Skip to main content

Power - Triode (over 1000V 100W) ·Triode

240B

Transmitting power triode intended for RF amplifier and oscillator service. Its manufacturer ratings and operating conditions identify it as a substantial radio-frequency power device suitable for transmitter applications.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
B4
Base pins
-
Nominal heater
20 V / 4 A

Description

The Western Electric 240B is a triode listed in the supplied catalog table. It is a water-cooled transmitting type intended for high-power RF service.

Socket description

European 4-pin base

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B4
Base pins
-
Nominal heater voltage
20 V
Nominal heater current
4 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.005 S
Amplification factor
40
Max plate voltage
12000 V
Max plate dissipation
10000 W

Published ratings/characteristics promoted from the approved datasheet.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1936 Cossor Valve Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Maximum anode current swing

    50 mA

    Published datasheet value

Data set 02

193X Cossor

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Filament/Heater Voltage

    20 V

    Published technical-data value

  • Filament/Heater Current

    4 A

    Published technical-data value

Data set 03

1956 Western Electric Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Maximum/Typical Power Output

    5000 W

    Catalog-table value

Other

  • Maximum Plate Voltage

    12000 V

    Catalog-table value

  • Maximum Plate Dissipation

    10000 W

    Catalog-table value