Compactron heater-cathode diode designed specifically for television horizontal-deflection damping service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
12FX
Socket code
B9A
Base pins
12
Nominal heater
22.4 V / 460 mA

Description

22BW3 is a damper diode for television horizontal-deflection service. The supplied RCA manual excerpt was reviewed for heater data, physical sections, maximum ratings, electrical characteristics, capacitances, and stated operating conditions.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
12FX
Socket code
B9A
Base pins
12
Nominal heater voltage
22.4 V
Nominal heater current
460 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

12FX - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Max plate dissipation
6.5 W
Rectifier peak inverse voltage
5000 V
Rectifier nominal output current
175 mA
Rectifier peak forward current
1.1 A
Rectifier forward voltage drop
32 V
Rectifier max heater-cathode voltage
5000 V
Rectifier warm-up time
11 s

Peak forward current uses published steady-state peak plate current. Heater-cathode field records largest published total DC-and-peak magnitude; polarity-specific limits are parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1961 Tung Sol

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Steady State Peak Plate Current

    1100 mA

    TVDamperService

Characteristic

  • Tube Voltage Drop

    32 V

    PlateCurrent=350mA

Data set 02

1966 Tung Sol Electronic Tubes 3 of 4

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Peak inverse plate voltage

    5000 V

    DamperService

  • Steady state peak plate current

    1000 mA

    DamperService

  • DC output current

    165 mA

    DamperService

  • Peak heater-cathode voltage

    5000 V

    HeaterNegative

  • Heater warm-up time

    11 s

Capacitance

  • Cathode-to-plate-and-heater capacitance

    8.5 pF

  • Plate-to-cathode-and-heater capacitance

    6 pF

  • Heater-to-cathode capacitance

    3.8 pF

Data set 03

1968 General Electric Co

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Heater Warm-up Time

    11 s

  • Heater-Cathode Voltage

    100 V

    HeaterPositive;DCComponent

  • Heater-Cathode Voltage

    300 V

    HeaterPositive;TotalDCAndPeak

  • Heater-Cathode Voltage

    900 V

    HeaterNegative;DCComponent

  • Heater-Cathode Voltage

    5000 V

    HeaterNegative;TotalDCAndPeak

Characteristic

  • Tube Voltage Drop

    32 V

    PlateCurrent=0.35A

Data set 04

1975 RCA RC30

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Heater Voltage (ac/dc) 16.8

    22.4 V

    Heater Voltage (ac/dc) 16.8 22.4 volts

  • Heater Current 0.6

    460 mA

    Heater Current 0.6 0.46 ampere

  • Heater Warm-up Time 11

    11 s

    Heater Warm-up Time 11 11 seconds

  • Peak Inverse Plate Voltage#

    5000 V

    Peak Inverse Plate Voltage# 5000 volts

  • Peak Plate Current

    1100 mA

    Peak Plate Current 1100 mA

  • Average Plate Current

    175 mA

    Average Plate Current 175 mA

  • Plate Dissipation

    6.5 W

    Plate Dissipation 6.5 watts

  • Peak inverse/negative-pulse plate voltage

    5000 V

    Published section value

  • Average output/plate current

    175 mA

    Published section value

Characteristic

  • Tube Voltage Drop for plate current of

    350 mA

    Tube Voltage Drop for plate current of 350 mA 32 volts

  • # Pulse duration must not exceed 15% of one horizontal scanning cycle (

    10 us

    # Pulse duration must not exceed 15% of one horizontal scanning cycle (10 microseconds).