Data set 01
1956 Western Electric Tubes
Published operating points and test conditions from this source.
Triode
Characteristics
Maximum/Typical Power Output
2200 W
Catalog-table value
Other
Maximum Plate Dissipation
5000 W
Catalog-table value
Power - Triode ·Triode
Forced-air-cooled high-power transmitting triode for RF service. Published data specify forced-air anode cooling, multi-kilowatt plate dissipation, and operation into the low-megahertz range for industrial transmitting applications.
The Western Electric 220CA is a triode listed in the supplied catalog table. It is a forced-air-cooled transmitting type intended for high-power RF service.
Medium 4-contact bayonet base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Promoted fields populated from explicitly published ratings/characteristics; service-specific data retained as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Maximum/Typical Power Output
2200 W
Catalog-table value
Maximum Plate Dissipation
5000 W
Catalog-table value
Data set 02
Published operating points and test conditions from this source.
Filament Starting Current
82 A
Available Thermionic Emission
7 A
Grid-Plate Capacitance
23.5 pF
Grid-Filament Capacitance
17.5 pF
Plate-Filament Capacitance
1.6 pF
RF Frequency Full Rating Maximum
4 MHz
Required Anode Airflow
600 cfm
Data set 03
Published operating points and test conditions from this source.
FilamentStartingCurrent
82 A
Peak Cathode Current
7 A
AnodeCoolingMethod
Forced Air
MaximumOperatingFrequency
4 MHz
Maximum Anode Dissipation
5000 W
Absolute maximum / applicable service
GridPlateCapacitance
23.5 pF
GridFilamentCapacitance
17.5 pF
Data set 04
Published operating points and test conditions from this source.
the ML
220
the ML-220CA is forced-air cooled and is capable of dis- exhausted by a straight-line, high-voltage process assuring the
peres apply at frequencics up to [1]
4 MHz
peres apply at frequencics up to 4 Mc; operation at 12 Mc is and super-voltage x-ray tubces,
peres apply at frequencics up to [2]
12 MHz
peres apply at frequencics up to 4 Mc; operation at 12 Mc is and super-voltage x-ray tubces,
permissible with plate voltage reduced to
5
permissible with plate voltage reduced to 5 kVde
Filament Current at
215 V
Filament Current at 21,5 volts e a1 amperes