Data set 01
195X General Electric Essential Characteristics
Published operating points and test conditions from this source.
Pentode
Characteristics
Input capacitance
3.6 pF
Output capacitance
7 pF
Grid-to-plate capacitance
0.1 pF
Plate resistance
250000 ohm
ClassA; OperatingPoint1
Transconductance
925 uS
ClassA; OperatingPoint1
Plate resistance
300000 ohm
ClassA; OperatingPoint2
Transconductance
875 uS
ClassA; OperatingPoint2
Plate resistance
400000 ohm
ClassA; OperatingPoint3
Transconductance
650 uS
ClassA; OperatingPoint3
Other
Plate voltage
90 V
ClassA; OperatingPoint1
Screen voltage
90 V
ClassA; OperatingPoint1
Control-grid bias
9 V
ClassA; OperatingPoint1
Plate current
5 mA
ClassA; OperatingPoint1
Screen current
1 mA
ClassA; OperatingPoint1
Load resistance
12000 ohm
ClassA; OperatingPoint1
Power output
0.2 W
ClassA; OperatingPoint1
Plate voltage
67.5 V
ClassA; OperatingPoint2
Screen voltage
67.5 V
ClassA; OperatingPoint2
Control-grid bias
6 V
ClassA; OperatingPoint2
Plate current
3.8 mA
ClassA; OperatingPoint2
Screen current
0.8 mA
ClassA; OperatingPoint2
Load resistance
16000 ohm
ClassA; OperatingPoint2
Power output
0.1 W
ClassA; OperatingPoint2
Plate voltage
45 V
ClassA; OperatingPoint3
Screen voltage
45 V
ClassA; OperatingPoint3
Control-grid bias
4.5 V
ClassA; OperatingPoint3
Plate current
1.6 mA
ClassA; OperatingPoint3
Screen current
0.3 mA
ClassA; OperatingPoint3
Load resistance
20000 ohm
ClassA; OperatingPoint3
Power output
0.035 W
ClassA; OperatingPoint3
Maximum plate voltage
110 V
Maximum screen voltage
110 V