Data set 01
195X General Electric Essential Characteristics
Published operating points and test conditions from this source.
Pentode
Characteristics
Input capacitance
3.2 pF
Output capacitance
3 pF
Grid-to-plate capacitance
0.25 pF
Other
Plate voltage
90 V
ClassA; OperatingPoint1
Screen voltage
67.5 V
ClassA; OperatingPoint1
Control-grid bias
0 V
ClassA; OperatingPoint1
Plate current
1.45 mA
ClassA; OperatingPoint1
Screen current
0.38 mA
ClassA; OperatingPoint1