Skip to main content

Voltage Radio Detector Converter ·Diode-Pentode

1Q6

Very-low-power battery diode-pentode combining signal detection with voltage amplification. The diode recovers the received signal while the pentode provides subsequent gain from an exceptionally economical directly heated filament.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
8CO
Socket code
-
Base pins
8
Nominal heater
1.25 V / 40 mA

Description

Combined detector diode and pentode amplifier for low-voltage battery receivers. Electrical ratings and representative operating data were extracted from the approved manual page.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
8CO
Socket code
-
Base pins
8
Nominal heater voltage
1.25 V
Nominal heater current
40 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

8CO - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

2 physical sections, each with unique specifications.

Section 1

Diode

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Detector diode section.

Section 2

Pentode

X-ray radiationInterelectrode capacitances
Plate resistance
400000 Ω
Transconductance
0.0006 S
Max plate voltage
100 V
Max screen voltage
100 V
Max cathode current
2 mA

Combined detector diode and pentode amplifier for low-voltage battery receivers.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1950 Sylvania

Published operating points and test conditions from this source.

SECTION 2

Pentode

Other

  • Plate Voltage

    30 V

  • Plate Voltage

    67.5 V

  • Screen Voltage

    30 V

  • Screen Voltage

    67.5 V

  • Plate Current

    0.33 mA

    30 V

  • Plate Current

    1.6 mA

    67.5 V

Data set 02

195X General Electric Essential Characteristics

Published operating points and test conditions from this source.

SECTION 2

Pentode

Characteristics

  • Input capacitance

    1.8 pF

  • Output capacitance

    4.2 pF

  • Grid-to-plate capacitance

    0.085 pF

Other

  • Plate voltage

    67.5 V

    ClassA; OperatingPoint1

  • Screen voltage

    67.5 V

    ClassA; OperatingPoint1

  • Control-grid bias

    0 V

    ClassA; OperatingPoint1

  • Plate current

    1.6 mA

    ClassA; OperatingPoint1

  • Screen current

    0.4 mA

    ClassA; OperatingPoint1

  • Plate voltage

    30 V

    ClassA; OperatingPoint2

  • Screen voltage

    30 V

    ClassA; OperatingPoint2

  • Control-grid bias

    0 V

    ClassA; OperatingPoint2

  • Plate current

    0.33 mA

    ClassA; OperatingPoint2

  • Screen current

    0.09 mA

    ClassA; OperatingPoint2