Data set 01
1948 Brimar Radio Valve Manual
Published operating points and test conditions from this source.
Pentode
Characteristic
HeaterOrFilamentVoltage
1.4 V
HeaterOrFilamentCurrent
50 mA
Voltage Pentode - Sharp Cutoff (single) ·Pentode
Directly heated sharp-cutoff pentode for RF and IF amplification in battery-operated receivers.
Sharp-cutoff RF pentode for battery receiver RF and IF service. Electrical ratings and representative operating data were extracted from the approved manual page.
International Octal
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Sharp-cutoff RF pentode for battery receiver RF and IF service.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
HeaterOrFilamentVoltage
1.4 V
HeaterOrFilamentCurrent
50 mA
Data set 02
Published operating points and test conditions from this source.
Plate Voltage
90 V
Screen Voltage
90 V
Plate Current
1.2 mA
Screen Current
0.3 mA
Plate Resistance
1.5 Mohm
Transconductance
750 µS
Grid 0 V
Transconductance
50 µS
Grid -3.2 V
Transconductance
5 µS
Grid -4 V
Data set 03
Published operating points and test conditions from this source.
Input capacitance
3 pF
Output capacitance
10 pF
Grid-to-plate capacitance
0.007 pF
Plate voltage
90 V
ClassA; OperatingPoint1
Screen voltage
90 V
ClassA; OperatingPoint1
Control-grid bias
0 V
ClassA; OperatingPoint1
Plate current
1.2 mA
ClassA; OperatingPoint1
Screen current
0.3 mA
ClassA; OperatingPoint1