Skip to main content

Specialized - Klystron ·Klystron

1K75CS

Ruggedized load-insensitive C-band reflex-klystron/isolator package designed for radio-altimeter service in the 4.2–4.4 GHz band.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.3 V / -

Description

Ruggedized, load-insensitive C-band reflex-klystron/isolator package intended for the 4200–4400 MHz radio-altimeter band.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Klystron

X-ray radiationInterelectrode capacitances
Max cathode current
86 mA

Reflex klystron: specialized resonator/repeller ratings have no direct promoted columns and are preserved in TUBE_SECTION_PARAMETER; published maximum cathode current is promoted.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Klystron

Characteristic

  • Frequency Range

    4200 to 4400 MHz

  • Published Output Power

    300 mW

    Minimum or typical as stated by source

  • Warm-up Time

    60 s

  • Heater Current

    1 A to 1.5 A

Other

  • Maximum DC Resonator Voltage

    900 V

  • Maximum Resonator Dissipation

    75 W

  • Maximum Negative Repeller Voltage

    500 V

    Negative with respect to cathode

  • Maximum Positive Repeller Voltage

    0 V

    Positive with respect to cathode

  • Typical DC Resonator Voltage

    700 V

  • Typical DC Cathode Current

    55 mA

  • Typical Power Output

    325 mW