Data set 01
1938 National Union
Published operating points and test conditions from this source.
Triode
Other
Pilament voltage
1.25 volts
Published source value; see source line context.
Plate voltage max
150 volts
Published source value; see source line context.
Plate dissipation max
3 watts
Published source value; see source line context.
Cathode current max
20 V
Published source value; see source line context.
Grid voltage when grid current max. =
0.2 volt
Published source value; see source line context.
Filament voltage max
1.55 volts
Published source value; see source line context.
Grid voltage
-3.5 volts
Published source value; see source line context.
Plate voltage
150 volts
Published source value; see source line context.
Frequency
470 megacycles
Published source value; see source line context.
Out put
0.45 watt
Published source value; see source line context.
the filament voltage must be at least
1.1 volts
Published source value; see source line context.
Plate voltage =
150 volts
Published source value; see source line context.
Characteristic
Filament current
0.22 amp
Published source value; see source line context.
Grid current meX
5 ma
Published source value; see source line context.
Grid circuit resistance
1 megohm
Published source value; see source line context.
Plate current
20 ma
Published source value; see source line context.
Cathode current
20 ma
Published source value; see source line context.
Grid current
1.5 ma
Published source value; see source line context.
Cathode current =
20 amps
Published source value; see source line context.