1B29 — Hydrogen-Argon Filled Spark Gap Modulator Tube
The 1B29 is a hydrogen-argon filled spark gap modulator tube designed specifically for triggered gap operation in modulator circuits, such as pulse-forming networks. To constitute a functioning triggered gap, a minimum of two 1B29 tubes must be connected in series.
Physical Construction and Mounting
The 1B29 is constructed within a glass bulb envelope and features two coaxial terminals of unequal dimensions:
- Large Terminal (Anode Side): Measures 0.820 inches in diameter by 5/8 inches in length, with a terminal diameter specification of 0.800" ± 0.007".
- Small Terminal (Cathode Side): Measures 0.580 inches in diameter by 7/16 inches in length, with a terminal diameter specification of 0.566" ± 0.007".
The tube can be mounted in any position. However, standard spring-type fuse clips should be avoided for mounting. Instead, the use of custom brackets, such as those made from #25 B&S Gauge phosphor-bronze spring temper, is recommended. The installation must ensure free air circulation around the glass envelope for adequate cooling and must protect the tube from excessive mechanical shock.
Electrical Ratings and Operating Limits
The operating limits for the 1B29 are defined by minimum, nominal, and maximum ratings. Operating the tube outside these boundaries can lead to circuit malfunction or physical damage.
| Parameter | Minimum | Nominal | Maximum | Conditions & Notes |
|---|---|---|---|---|
| Peak Voltage per Gap | — | 1.4 kV | 1.5 kV | Voltages exceeding 1.5 kV cause continuous arcing |
| Peak Voltage (Any Number of Gaps) | 2.6 kV | — | — | Minimum threshold below which intermittent action or cessation occurs |
| Starting Voltage | — | — | 1.9 kV | Measured in a two-tube circuit with a 2.8 kV peak trigger voltage |
| Peak Trigger Voltage | 2.7 kV | 3.0 kV | 3.5 kV | Measured at the sockets with the tubes removed and equivalent capacities substituted |
| Fundamental Trigger Frequency | 0.018 Mc | — | 0.4 Mc | Applicable for a damped oscillation trigger pulse |
| Peak Current | 20 A | — | 30 A | Permissible for short intervals |
| Repetition Rate | 500 pps | 2000 pps | 2100 pps | Nominal rate is 2000 pps |
| Pulse Duration | 0.4 usec | — | 0.75 usec | |
| Interelectrode Capacitance | — | 1.4 uuf | — |
Circuit-Specific Operation and Triggering
In a typical two-tube circuit configuration, the series combination stands off approximately 3 kV. This configuration typically employs resonance charging, which causes the peak voltage across the switching tubes to reach approximately twice the value of the d-c supply voltage. During the discharge of the pulse-forming network, the voltage across the gaps drops to approximately 150 V. In practical modulator circuits, the ratio of the peak load voltage to the d-c supply voltage ranges from 0.7 to 0.75.
To ensure reliable starting when returning to normal operating conditions, the d-c power supply must have a no-load voltage of at least 1.9 kV. Additionally, an overload relay should be installed in the d-c supply lead and set to trip at approximately 60 mA d-c to prevent damage to the tubes in the event of continuous arcing.
Triggering Requirements
The trigger pulse applied to the 1B29 should ideally be a damped oscillation characterized by a high decrement. A trigger amplitude of 2.8 kV or greater is sufficient to ionize both gaps, which effectively lowers the starting voltage of the system. If unidirectional trigger pulses are used instead of oscillatory pulses, a higher starting voltage is required.
Proper power-up sequencing is critical: the trigger voltage must be applied to the spark gap tubes before the d-c power supply is turned on. Failing to follow this sequence can result in over-voltage arcing on the second pulse.
Series Operation and Multi-Gap Configurations
For applications requiring higher operating voltages, multiple 1B29 tubes can be connected in series. This configuration increases the overall operating range of the system because the maximum peak voltage capability rises with each added tube, while the minimum peak voltage threshold remains constant at 2.6 kV. This relationship holds true provided that the voltage is divided equally across all gaps and that a sufficient trigger voltage is supplied to the junction points via coupling condensers.
However, using more than four gaps in series is not recommended. Beyond four gaps, difficulties arise regarding equal voltage division and the loading of the trigger circuit. Furthermore, care must be taken to avoid reverse current resulting from impedance mismatch, as reverse current significantly shortens the operating life of the tubes.
Technical Summary
The 1B29 is a specialized hydrogen-argon filled spark gap modulator tube designed for high-power pulse-forming networks. It features a glass envelope with asymmetrical coaxial terminals and is rated for a nominal peak voltage of 1.4 kV per gap (1.5 kV maximum) and a peak current of up to 30 A for short intervals. Triggered operation requires a minimum of two tubes in series, utilizing a damped oscillation trigger pulse between 2.7 kV and 3.5 kV. While series operation allows higher voltage handling, configurations are practically limited to a maximum of four gaps to ensure reliable triggering and voltage division.
General specifications
Tube and section characteristics
Properties common to every published source and operating point.
Heater and base
- Base
- -
- Socket code
- -
- Base pins
- -
- Nominal heater voltage
- -
- Nominal heater current
- -
- Parallel heater voltage
- -
- Parallel heater current
- -
- Series capable
- No
Terminal pinout
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
Section ratings
1 physical section, each with unique specifications.
Section 1
MicrowaveTRSwitch
No fixed ratings are recorded for this section.
Published ratings and characteristics promoted where applicable; additional useful values retained as parameters.
Source-dependent data
Operating conditions by source
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.