Data set 01
1960 Mazda
Published operating points and test conditions from this source.
Rectifier
Characteristics
No-load peak inverse voltage
23 kV
Minimum surge-limiting resistance
23000 Ohm
Warmup time
10 s
Rectifier - Half Wave ·Rectifier
High-voltage industrial half-wave rectifier for demanding power-supply service. Its multi-kilovolt inverse-voltage capability and modest current output suit specialized professional DC systems.
The 19H4 (also designated as the 19.H.4) is a high-vacuum diode designed specifically for high-voltage power rectification. Manufactured by companies such as Associated Electrical Industries Limited (AEI) / Ediswan and Mazda, this device is engineered to handle extremely high peak inverse voltages, making it suitable for specialized power supply and rectification roles.
The 19H4 is constructed with a clear glass envelope and features an American Miniature Type top cap, which serves as the connection point for the anode. The tube utilizes an International Octal (IO8) base. It is designed for unrestricted mounting, allowing it to be installed in any physical orientation.
The physical envelope of the 19H4 is characterized by the following maximum dimensions:
The weight of the device varies slightly depending on the manufacturing specification:
The base connections, viewed from the free end of the pins, are assigned as follows:
A critical wiring requirement is specified for the socket holder: all pins with the exception of Pin 2 must be connected directly to Pin 7 on the holder, and Pin 7 must then be connected to the reservoir condenser.
The 19H4 operates with a nominal heater voltage of 2.5 V. However, the documentation reflects differing specifications regarding the heating method and current requirements depending on the manufacturer:
Regardless of the heating configuration, a pre-heating period is required under delayed switching conditions, where the heater must be energized for at least 10 seconds before the anode voltage is applied.
The average operating characteristics of the 19H4 describe the relationship between anode voltage and anode current. The tube exhibits a typical diode exponential start at lower voltages, transitioning into a highly linear region as voltage increases.
Specifically, the curve starts at 0 V and 0 mA, showing a non-linear upward trend up to approximately 100 V to 120 V. From 120 V up to the upper measurement limits of 340 V to 360 V, the relationship becomes highly linear. Typical operating points extracted from the characteristic curves include:
The maximum ratings for the 19H4 are defined as absolute values rather than design centers. These limits depend heavily on whether the circuit employs delayed switching or simultaneous switching.
When the heater is allowed to warm up for at least 10 seconds before anode voltage is applied, the tube can be operated at its full power capability:
If the heater and anode voltages are applied simultaneously, the maximum ratings are significantly reduced to protect the tube:
To prevent damage from inrush currents and excessive loading, specific circuit parameters must be maintained:
The 19H4 is a high-vacuum diode designed for high-voltage power rectification. It features an International Octal base, a clear glass envelope, and an American Miniature top cap for the anode. Operating with a 2.5 V heater, its current draw is specified as either 1.7 A or 3.3 A depending on whether it is configured as an indirectly or directly heated device. The tube is capable of handling peak inverse voltages up to 23.0 kV under no-load conditions and mean anode currents up to 30.0 mA when a 10-second delayed switching sequence is observed. Proper circuit design requires a minimum surge limiting resistance of 18,000 to 23,000 ohms and strict adherence to reservoir capacitor limits to ensure reliable operation.
International Octal
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
REDO promoted-field audit
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
No-load peak inverse voltage
23 kV
Minimum surge-limiting resistance
23000 Ohm
Warmup time
10 s
Data set 02
Published operating points and test conditions from this source.
No-load peak inverse voltage
23 kV
Delayed-switching mean anode current
5 mA
Data set 03
Published operating points and test conditions from this source.
No-load peak inverse voltage
23 kV
Delayed-switching mean anode current
5 mA