Rectifier - Half Wave ·Rectifier

1859

Philips directly heated mercury-vapor/gas high-current cinema rectifier, providing approximately 25 A DC and exceptionally high peak-current capability for industrial supplies.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
1.9 V / 60 A

Description

1859 — Double-Anode Mercury Vapour and Gas-Filled Rectifying Valve

The 1859 is a heavy-duty, double-anode rectifying valve filled with mercury vapour and gas. Designed primarily for high-current applications such as cinema rectifiers, it is capable of delivering up to 50 A per valve. The device features an oxide-coated, directly heated filament operating at a very low voltage and extremely high current.

Mechanical Design and Physical Specifications

The 1859 is a physically large valve, constructed with a robust glass bulb and heavy-duty threaded terminals to handle high currents.

  • Mounting Position: Must be mounted vertically, base down.
  • Dimensions: Maximum diameter of 143 mm and a maximum height of 436 mm.
  • Weight: Net weight is 1650 g, with a shipping weight of 3800 g.
  • Terminals:
    • Top Caps: Two M8 threaded terminals with 50 mm spacing, serving as the connections for the two anodes (a, a').
    • Base: M4 threaded terminals for the auxiliary ignition electrode (ah) and the filament/cathode connections (f, f).

Filament and Pre-heating Requirements

The 1859 utilizes an oxide-coated filament designed for direct heating via an alternating current (A.C.) supply. Due to the high thermal mass and the mercury-vapour filling, strict pre-heating schedules must be observed to prevent damage to the cathode during ignition.

ParameterValue
Filament Voltage (VfV_f)1.9 V
Filament Current (IfI_f)60 A
Calculated Filament Power114 W

Pre-heating Schedule

  • Standard Operation: A recommended pre-heating time (TwT_w) of 2 minutes is required before applying anode voltage. In urgent situations, this delay can be reduced to a minimum of 1 minute. A time delay switch (such as type 4152) can be used to automate this delay.
  • Commissioning and Maintenance: After transport or a long period of service interruption, the valve must be pre-heated for at least 5 minutes to ensure proper distribution of the mercury vapour before drawing current.

Electrical and Ignition Characteristics

The 1859 exhibits a low internal voltage drop typical of gas and mercury-vapour rectifiers.

  • Arc Voltage (VarcV_{arc}): 12 V (typical operating voltage drop across the valve during conduction).
  • Ignition Voltage (VignV_{ign}): 28 V.

Auxiliary Ignition System

To reliably initiate conduction at an ignition voltage of 28 V, the 1859 requires an auxiliary ignition circuit. An auxiliary D.C. supply delivering a minimum of 40 V and 10 mA must be connected between the auxiliary ignition electrode (aha_h, positive terminal) and the cathode (negative terminal). This connection must be made via a current-limiting resistor to protect the ignition electrode. The Philips Auxiliary Ignition Unit type 1289 is recommended for this purpose.

Operating Configurations

The 1859 can be operated in several circuit configurations to deliver varying output voltages (VoV_o) and currents (IoI_o) from an effective transformer secondary voltage (VtrV_{tr}).

Circuit ConfigurationTransformer Voltage (VtrV_{tr})Output Voltage (VoV_o)Output Current (IoI_o)
a115 VeffV_{eff}85 V50 A
e115 VeffV_{eff}120 V100 A
f105 VeffV_{eff}120 V150 A
g115 VeffV_{eff}110 V150 A

Absolute Maximum Ratings

To ensure the longevity and safe operation of the mercury-vapour and gas-filled envelope, the following absolute limits must not be exceeded:

  • Peak Inverse Anode Voltage (VainvpV_{ainv_p}): Maximum 360 V.
  • Average Anode Current (IaI_a): Maximum 25 A per anode, calculated over a maximum averaging time (TavT_{av}) of 15 seconds.
  • Peak Anode Current (IapI_{ap}): Maximum 150 A.
  • Surge Current (IsurgeI_{surge}): Maximum 1250 A for a maximum duration (TT) of 0.1 seconds (intended as a safety rating for short-circuit or fault conditions).
  • Minimum Series Resistance (RtR_t): Minimum 0.1 \Omega must be present in the anode circuit to limit peak currents.
  • Mercury Temperature (tHgt_{Hg}): The operating temperature of the mercury condensed at the bottom of the bulb must be maintained strictly between 30 °C and 80 °C.

Technical Summary

The 1859 is a high-power, double-anode, mercury-vapour and gas-filled rectifying valve designed for demanding industrial and cinema projection applications. Operating with a high-current 1.9 V, 60 A filament, it requires careful pre-heating and an auxiliary D.C. ignition supply to establish its low-loss 12 V arc. With a peak inverse voltage rating of 360 V and the capability to support output currents up to 150 A in multi-valve configurations, the 1859 provides a highly efficient and robust solution for heavy-duty D.C. power rectification, provided its strict thermal and electrical limits are maintained.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
1.9 V
Nominal heater current
60 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
360 V
Rectifier nominal output current
25 A
Rectifier peak forward current
150 A
Rectifier forward voltage drop
12 V
Rectifier warm-up time
2 s

Promoted only where the locked section schema has a direct semantic match; additional published device-specific ratings, operating points, capacitances, life-test, pulse, RF, and rectifier data are retained in TUBE_SECTION_PARAMETER.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Philips Electron Tubes Handbook V3

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Filament heating time

    2 s

    IndustrialRectifier

  • Arc voltage drop

    12 V

    IndustrialRectifier

  • Ignition voltage

    28 V

    IndustrialRectifier

Other

  • Peak inverse anode voltage maximum

    360 V

    IndustrialRectifier

  • Average anode current maximum

    25 A

    IndustrialRectifier

  • Peak anode current maximum

    150 A

    IndustrialRectifier

  • Surge current maximum

    1250 A

    IndustrialRectifier

  • Recommended temperature range

    30-80 °C

    IndustrialRectifier

  • Transformer RMS voltage

    115 V

    CircuitA

  • DC output voltage

    85 V

    CircuitA

  • DC output current

    50 A

    CircuitA

  • Transformer RMS voltage

    115 V

    CircuitE

  • DC output voltage

    120 V

    CircuitE

  • DC output current

    100 A

    CircuitE

  • Transformer RMS voltage

    105 V

    CircuitF

  • DC output voltage

    120 V

    CircuitF

  • DC output current

    150 A

    CircuitF

  • Transformer RMS voltage

    115 V

    CircuitG

  • DC output voltage

    110 V

    CircuitG

  • DC output current

    150 A

    CircuitG