Skip to main content

Rectifier - Full Wave ·Rectifier-Rectifier

1831

Philips directly heated full-wave high-vacuum rectifier for receiver and general power-supply service. Its dual-anode arrangement provides moderate-current full-wave AC rectification from a four-volt filament.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
-
Socket code
-
Base pins
-
Nominal heater
4 V / 1 A

Description

1831 — Full-Wave High-Vacuum Rectifier

The 1831 is a full-wave high-vacuum rectifier valve designed specifically for use in alternating current (A.C.) mains receivers. It features a directly heated filament and is capable of handling high anode voltages while delivering a rectified direct current suitable for powering receiver circuitry.

Construction, Filament, and Physical Dimensions

The 1831 is constructed as a full-wave rectifier (also described as Vollweg Hochvakuum or Biplaque à vide poussé), containing two anode plates and a directly heated filament.

Filament Ratings

The filament is designed for direct heating and operates under the following nominal electrical conditions:

  • Filament Voltage (Vf): 4.0 V
  • Filament Current (If): Approximately 1.0 A

Physical Dimensions and Basing

The tube is equipped with an A35 base, with documentation referencing base connection S III (also designated as connection reference 5). The physical dimensions of the envelope are as follows:

  • Maximum Overall Length (l): 145 mm (excluding pins)
  • Maximum Diameter (d): 59 mm

Maximum Ratings

To ensure reliable operation and prevent damage to the valve, the operating conditions must be kept within the specified maximum ratings:

  • Maximum A.C. Anode Voltage (Va max): 2 x 700 V RMS (no-load)
  • Maximum Rectified Current (Ia max): 60 mA (D.C. current)

Operating Characteristics and Performance Curves

The performance of the 1831 rectifier is characterized by the relationship between the rectified output voltage (Va) and the delivered rectified current (Ia) across its operating range up to 64 mA. The output voltage behavior varies depending on the effective input voltage (Veff) applied to the anodes:

  • At Veff = 2 x 700 V:
    • No-load output voltage (0 mA): ~980 V
    • Loaded output voltage at 60 mA: ~800 V
  • At Veff = 2 x 600 V:
    • No-load output voltage (0 mA): ~840 V
    • Loaded output voltage at 60 mA: ~670 V
  • At Veff = 2 x 500 V:
    • No-load output voltage (0 mA): ~700 V
    • Loaded output voltage at 60 mA: ~540 V

These values demonstrate the typical voltage regulation of the rectifier under load, showing a predictable drop in output voltage as the current demand increases from zero to the maximum rated limit of 60 mA.

Technical Summary

The 1831 is an A35-based, directly heated, full-wave high-vacuum rectifier valve designed for A.C. mains receivers. Utilizing a 4.0 V, 1.0 A filament, it supports a maximum A.C. anode voltage of 2 x 700 V RMS and delivers up to 60 mA of rectified D.C. current. Housed in a 145 mm by 59 mm envelope with an S III (reference 5) connection, the 1831 provides stable high-voltage rectification with well-defined output characteristics across input levels from 2 x 500 V to 2 x 700 V.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
4 V
Nominal heater current
1 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

2 physical sections, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Max plate voltage
700 V
Rectifier nominal output current
60 mA

Directly heated full-wave high-vacuum rectifier.

Section 2

Rectifier

X-ray radiationInterelectrode capacitances
Max plate voltage
700 V
Rectifier nominal output current
60 mA

Second physical rectifier section; electrical properties populated from corresponding identical section.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1938 Philips Miniwatt Vacuum Tube Catalog

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Maximum AC no-load voltage per plate

    700 V

    FullWave

  • Maximum DC output current

    60 mA

    FullWave

SECTION 2

Rectifier

Other

  • Maximum AC no-load voltage per plate

    700 V

    FullWave

  • Maximum DC output current

    60 mA

    FullWave

Data set 02

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Heater voltage

    40 V

    Nominal

  • Heater current

    1 A

    Nominal

  • A.C. anode voltage

    700 V

    Maximum

  • Rectified current

    60 mA

    Maximum

SECTION 2

Rectifier

Other

  • Heater voltage

    40 V

    Nominal

  • Heater current

    1 A

    Nominal

  • A.C. anode voltage

    700 V

    Maximum

  • Rectified current

    60 mA

    Maximum