Skip to main content

Rectifier - Full Wave ·Rectifier-Rectifier

1801

Philips directly heated full-wave high-vacuum rectifier for AC mains receiver power supplies. Its dual-anode structure provides modest B-plus current for lower-power mains-operated radio equipment.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
A35
Socket code
-
Base pins
-
Nominal heater
4 V / 500 mA

Description

1801 — Full-Wave High-Vacuum Rectifier

A directly heated, full-wave high-vacuum rectifier designed for AC mains receivers and low-power rectification applications.

Overview

The 1801 (also designated as a Vollweg Hochvakuum or Biplaque à vide poussé rectifier) is a full-wave high-vacuum rectifier valve. It is designed primarily for AC mains receivers, providing rectified DC power from an alternating current source. The device features a directly heated filament and two anode plates (full-wave configuration) housed in a glass envelope with a standard European base.

Mechanical Design, Base, and Physical Dimensions

The 1801 is constructed with a glass envelope and utilizes an A35 base. Depending on the technical specification registry, the base connection is designated as connection reference 5 or S III.

The physical dimensions of the valve are compact, making it suitable for standard AC mains receiver chassis of its era:

  • Maximum Overall Length: 93 mm (excluding the base pins)
  • Maximum Diameter: 47 mm

The dual-anode structure within the single envelope allows for efficient full-wave rectification without requiring two separate half-wave rectifier tubes, saving space and reducing circuit complexity.

Filament and Electrical Ratings

The 1801 utilizes a directly heated filament. The filament is designed for low-voltage operation, typical of European AC receiver designs. The electrical ratings for the filament and the maximum operating limits of the anodes are as follows:

Filament Ratings

  • Filament Voltage (VfV_f): 4.0 V
  • Filament Current (IfI_f): Approximately 0.4 A to 0.5 A
  • Heating Method: Direct

Maximum Ratings

To ensure reliable operation and prevent damage to the filament and anode structures, the operating conditions must not exceed the following absolute maximum limits:

  • Maximum AC Anode Voltage (VaV_a or VeffV_{\text{eff}}): $2 \times 250\text{ V}_{\text{RMS}}$
  • Maximum Rectified DC Current (IaI_a): 30 mA

Operating Characteristics and Rectification Performance

The 1801 exhibits a typical high-vacuum rectifier voltage-drop characteristic under load. Because it is a high-vacuum device (rather than a mercury-vapor rectifier), its internal resistance causes the output DC voltage (rectified voltage, VdV_d) to decrease as the load current (rectified current, IaI_a) increases.

The relationship between the rectified voltage and the output current is documented across three typical AC input voltage levels:

1. Input Voltage: $2 \times 250\text{ V}_{\text{RMS}}$

At the maximum rated AC input voltage, the rectified output voltage behaves as follows:

  • No-load condition (0 mA): The rectified voltage is approximately 350 V.
  • Full-load condition (30 mA): The rectified voltage drops to approximately 240 V.

2. Input Voltage: $2 \times 200\text{ V}_{\text{RMS}}$

At a reduced AC input voltage of $2 \times 200\text{ V}$, the output voltage drops proportionally:

  • No-load condition (0 mA): The rectified voltage is approximately 280 V.
  • Full-load condition (30 mA): The rectified voltage drops to approximately 175 V.

3. Input Voltage: $2 \times 150\text{ V}_{\text{RMS}}$

At the lowest documented AC input voltage of $2 \times 150\text{ V}$, the output voltage is:

  • No-load condition (0 mA): The rectified voltage is approximately 210 V.
  • Full-load condition (30 mA): The rectified voltage drops to approximately 110 V.

These operating points demonstrate the internal resistance of the tube. For example, at an input of $2 \times 250\text{ V}_{\text{RMS}},acurrentdrawincreaseof30mAresultsinaninternalvoltagedropofapproximately110V(, a current draw increase of 30 mA results in an internal voltage drop of approximately 110 V (350\text{ V} - 240\text{ V} = 110\text{ V}$). This characteristic must be accounted for in power supply filter design, particularly when selecting smoothing capacitors and choke values to maintain stable HT (high-tension) rails in AC receivers.

Technical Summary

The 1801 is a classic directly heated, full-wave high-vacuum rectifier designed for low-power AC mains receivers. Operating with a 4.0 V filament supply drawing between 0.4 A and 0.5 A, it provides reliable full-wave rectification. It supports a maximum AC input voltage of $2 \times 250\text{ V}_{\text{RMS}}$ and delivers a maximum rectified DC current of 30 mA. Housed in an envelope with a maximum length of 93 mm and a diameter of 47 mm, and utilizing an A35 base, the 1801 is a highly specialized component optimized for stable, low-current high-voltage DC generation.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
A35
Socket code
-
Base pins
-
Nominal heater voltage
4 V
Nominal heater current
500 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

A35 - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

2 physical sections, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier nominal output current
30 mA

Directly heated full-wave high-vacuum rectifier for AC mains receivers.

Section 2

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier nominal output current
30 mA

Second physical rectifier section; electrical properties populated from corresponding identical section.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1938 Philips Miniwatt Vacuum Tube Catalog

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Maximum AC no-load voltage per plate

    250 V

    FullWave

  • Maximum DC output current

    30 mA

    FullWave

SECTION 2

Rectifier

Other

  • Maximum AC no-load voltage per plate

    250 V

    FullWave

  • Maximum DC output current

    30 mA

    FullWave

Data set 02

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • RMS anode voltage per plate

    250 V

  • Rectified output current

    30 mA

SECTION 2

Rectifier

Other

  • RMS anode voltage per plate

    250 V

  • Rectified output current

    30 mA