Data set 01
1970 Sylvania Technical Manual
Published operating points and test conditions from this source.
Beam Power
Characteristics
Plate Voltage
250 V
Screen Voltage
150 V
Grid Bias
-22.5 V
Plate Current
70 mA
Screen Current
2.1 mA
Other
Peak positive pulse plate voltage
6500 V
peak positive plate voltage; Sylvania 1970
Peak negative pulse plate voltage
-1500 V
peak negative plate voltage; Sylvania 1970
Average cathode current
175 mA
average cathode maximum; Sylvania 1970
Peak cathode current
550 mA
peak cathode maximum; Sylvania 1970
Heater warm-up time
11 s
heater warmup; Sylvania 1970
Grid #1 voltage
-42 V
cutoff Ib1mA; Sylvania 1970
Plate voltage
60 V
knee plate voltage; Sylvania 1970
Plate current
390 mA
knee plate current; Sylvania 1970
Grid #2 current
32 mA
knee screen current; Sylvania 1970
Bulb Temperature (At hottest point)
240 degC
max bulb temperature; Sylvania 1970
Peak Heater-Cathode Voltage
200 V
heater negative DC+peak; Sylvania 1970
Peak Heater-Cathode Voltage
100 V
heater positive DC; Sylvania 1970
Peak Heater-Cathode Voltage
200 V
heater positive DC+peak; Sylvania 1970
Capacitance
Grid-to-plate capacitance
0.26 pF
grid-plate capacitance; Sylvania 1970
Input capacitance
15 pF
input capacitance; Sylvania 1970
Output capacitance
6.5 pF
output capacitance; Sylvania 1970