Data set 01
1970 Sylvania Technical Manual
Published operating points and test conditions from this source.
Beam Power
Characteristics
Plate Voltage
250 V
Screen Voltage
150 V
Grid Bias
-22.5 V
Plate Current
57 mA
Screen Current
2.1 mA
Other
Peak positive pulse plate voltage
5500 V
peak positive plate voltage; manufacturer datasheet
Peak negative pulse plate voltage
-1250 V
peak negative plate voltage; manufacturer datasheet
Average cathode current
110 mA
average cathode current maximum; manufacturer datasheet
Peak cathode current
400 mA
peak cathode current maximum; manufacturer datasheet
Heater warm-up time
11 s
heater warmup; Sylvania 1970
Grid #1 voltage
-43 V
grid cutoff at plate current 1mA; Sylvania 1970
Plate voltage
60 V
knee plate voltage; Sylvania 1970
Plate current
260 mA
knee plate current; Sylvania 1970
Grid #2 current
26 mA
knee screen current; Sylvania 1970
Plate voltage
250 V
typical plate voltage; Sylvania 1970
Grid #2 voltage
150 V
typical screen voltage; Sylvania 1970
Grid #1 voltage
-22.5 V
typical grid voltage; Sylvania 1970
Plate current
57 mA
typical plate current; Sylvania 1970
Grid #2 current
2.1 mA
typical screen current; Sylvania 1970
Capacitance
Grid-to-plate capacitance
0.5 pF
grid plate capacitance; manufacturer datasheet
Input capacitance
14 pF
input capacitance; manufacturer datasheet
Output capacitance
7 pF
output capacitance; Sylvania 1970