Rectifier - Half Wave ·Rectifier

1788

Philips directly heated gas-filled industrial half-wave rectifier for charging lead-acid batteries, providing approximately 5 A DC output and high peak-current capability.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
GOLIATH
Socket code
-
Base pins
-
Nominal heater
1.9 V / 11 A

Description

1788 — Double-Anode Mercury Vapour and Gas-Filled Rectifying Valve

Overview

The 1788 is a heavy-duty, double-anode rectifying valve containing both mercury vapour and gas filling. It is designed specifically for high-current rectification applications, most notably in battery chargers. A single 1788 valve is capable of delivering up to 10 A of charging current, making it suitable for charging banks of up to 36 lead-acid (Pb) cells.

The tube features a robust mechanical construction, utilizing a GOLIATH base and top-mounted anode terminals to handle high currents and voltages safely. Its operation relies on a low-voltage, high-current directly heated filament and requires careful thermal and electrical management, including a dedicated pre-heating schedule and a specific screen connection.

Mechanical and Physical Specifications

The 1788 is constructed with a large glass bulb envelope to facilitate heat dissipation during high-power operation. The physical dimensions and installation requirements are as follows:

  • Mounting Position: The valve must be mounted strictly in a vertical position, with the base pointing down. This orientation is critical to ensure the proper distribution and condensation of the mercury vapour during operation.
  • Dimensions: The envelope has a maximum overall height of 284 mm and a maximum diameter of 94 mm.
  • Weight: The net weight of the valve is 350 g, while its shipping weight is 3000 g, reflecting the substantial protective packaging required for transport.
  • Base and Socket: The tube is equipped with a GOLIATH base and is designed to fit a type 65909 BG/01 socket.
  • Electrode Connections:
    • Anodes: The two anodes are connected via two top terminals of M6 size.
    • Screen: The screen (ss) is connected via a side terminal of M4 size, which has a maximum projection of 13 mm.

Filament and Pre-heating Requirements

The 1788 utilizes an oxide-coated, directly heated filament designed for alternating current (A.C.) operation. Due to the high-current nature of the tube, the filament demands a substantial current supply at a very low voltage:

ParameterValue
Filament Voltage (VfV_f)1.9 V (A.C.)
Filament Current (IfI_f)11 A

Pre-heating Schedule

Because the 1788 is a mercury vapour and gas-filled tube, the filament must be pre-heated before anode voltage is applied. This ensures that the mercury is sufficiently vaporized and the cathode reaches its proper operating temperature, preventing damage to the oxide coating from ion bombardment.

  • Standard Pre-heating Time (TwT_w): A minimum of 2 minutes is recommended under normal operating conditions.
  • Urgent Operation: In urgent cases, the pre-heating time can be reduced to a minimum of 1 minute. A type 4152 time delay switch may be integrated into the control circuitry to automate this delay.
  • Post-Transport / Long Interruption: After transport or a long period of service interruption, the valve must be pre-heated for at least 5 minutes to ensure all condensed mercury is cleared from the electrodes.

Electrical Characteristics and Operating Limits

The electrical behavior of the 1788 is characterized by a low internal voltage drop once the arc is established, which is typical of gas and mercury vapour rectifiers.

Typical Characteristics

  • Ignition Voltage (VignV_{ign}): 22 V (the minimum voltage required to initiate conduction).
  • Arc Voltage (VarcV_{arc}): 9 V (the constant voltage drop across the tube during conduction).

Limiting Values (Absolute / Design-Maximum)

To ensure reliable operation and prevent premature valve failure, the following limiting values must not be exceeded:

ParameterLimit Value
Maximum Transformer Voltage (VtrV_{tr})95 VeffV_{eff} (applicable for "Circuit a")
Minimum Transformer Voltage (VtrV_{tr})20 VeffV_{eff} (applicable for "Circuit a")
Maximum Peak Inverse Anode Voltage (VainvpV_{ainv_p})300 V
Maximum Continuous Anode Current (IaI_a)5 A
Maximum Peak Anode Current (IapI_{ap})30 A
Minimum Surge Limiting Resistance (RtR_t)0.3 Ω\Omega
Mercury Condensation Temperature (tHgt_{Hg})30 to 80 ^\circ C

The minimum surge limiting resistance of 0.3 Ω\Omega is a critical circuit requirement to protect the anodes from excessive current surges during start-up or transient conditions. Additionally, the mercury condensation temperature must be maintained strictly within the 30 to 80 ^\circ C range to ensure stable gas pressure and prevent arc-back or failure to ignite.

Circuit and Application Requirements

In practical applications, the 1788 requires specific external circuitry to function correctly and safely.

Screen Connection

The screen (ss) must not be left floating. It is a strict operational requirement that the screen terminal (M4 side terminal) be connected directly to the cathode via a 10 kΩ\Omega, 0.5 W resistor. This resistor limits the screen current and stabilizes the internal potential of the tube during the ignition and conduction phases.

Battery Charging Service

When configured as a full-wave rectifier using both anodes, the 1788 is capable of delivering a maximum charging current of 10 A per valve. This high current capacity allows the system to charge up to 36 lead-acid (Pb) cells connected in series. The transformer voltage must be selected within the specified 20 to 95 VeffV_{eff} range to match the battery bank voltage while respecting the maximum peak inverse voltage of 300 V.

Technical Summary

The 1788 is a specialized double-anode mercury vapour and gas-filled rectifying valve designed for high-current battery charging applications. It features a GOLIATH base, top-mounted M6 anode terminals, and an M4 side screen terminal. The valve operates with a 1.9 V, 11 A directly heated filament and requires a strict pre-heating routine (typically 2 minutes) to safeguard its oxide-coated cathode. With an ignition voltage of 22 V and a low arc drop of 9 V, the 1788 efficiently handles continuous anode currents up to 5 A per anode (10 A total per valve) and peak currents up to 30 A, under a maximum peak inverse voltage of 300 V. Safe operation requires a minimum surge limiting resistance of 0.3 Ω\Omega, a screen-to-cathode connection via a 10 kΩ\Omega resistor, and a controlled mercury condensation temperature between 30 and 80 ^\circ C.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
GOLIATH
Socket code
-
Base pins
-
Nominal heater voltage
1.9 V
Nominal heater current
11 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

GOLIATH - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
300 V
Rectifier nominal output current
5 A
Rectifier peak forward current
30 A
Rectifier forward voltage drop
9 V
Rectifier warm-up time
120 s

Directly heated gas-filled rectifier with mercury-vapour/gas filling for battery charging up to 36 lead-acid cells.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Philips Electron Tubes Handbook V3

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Arc voltage drop

    9 V

    GasFilled

Other

  • Maximum peak inverse anode voltage

    300 V

  • Maximum average anode current

    5 A

  • Maximum peak anode current

    30 A

  • Application

    battery charging up to 36 lead-acid cells

  • Heater voltage

    1.9 V

    DirectAC

  • Heater current

    11 A

    DirectAC

Data set 02

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Maximum RMS anode supply voltage

    95 V

  • Minimum RMS anode supply voltage

    20 V

  • Maximum average anode current per anode

    5 A

  • Permitted mercury/ambient temperature

    30 to 80 degC

  • DC output current

    10 A