Specialized - Thyratron ·Thyratron

1754

Hydrogen-reservoir grid-controlled thyratron for high-repetition-rate, high-current, high-voltage pulse service. Reservoir control maintains suitable gas pressure for fast switching.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.3 V / 2.53 A

Description

1754 — Heavy-Duty Hydrogen Thyratron

The 1754 is a heavy-duty, hot-cathode, grid-controlled gas thyratron equipped with an integrated hydrogen reservoir. It is designed specifically for high-repetition-rate pulsing service under conditions of high current and high voltage.

Overview and Applications

The 1754 is engineered to handle demanding pulse-generation and switching tasks. Its primary applications include:

  • Switching or clipping in radar modulators
  • Switching in welding circuits
  • High-power pulse generators
  • Magnetron aging

The tube utilizes a hydrogen gas medium, which is regulated by an internal reservoir to maintain optimal operating pressure.

Mechanical and Environmental Specifications

The physical construction and environmental limits of the 1754 are designed to support high-power operation:

  • Envelope: T-40 glass bulb.
  • Top Cap: Features a diameter of 0.500 inches and a height of 0.566 inches (±0.007 inches).
  • Mounting: Must be mounted in a vertical position only. Clamping is permissible by the base only.
  • Cooling: No cooling stream of air should be directly applied to the tube envelope.
  • Ambient Temperature Range: -55 to 75°C.
  • External Fields: The tube must be kept away from strong external fields that could cause unwanted ionization of the gas.

Heater and Hydrogen Reservoir Requirements

The 1754 requires separate electrical supplies for its cathode heater and its hydrogen reservoir.

Heater Characteristics

The cathode is an indirectly heated type requiring a significant heating current and a mandatory warm-up period before anode voltage is applied.

  • Heater Voltage: 6.3 Volts (±7.5%)
  • Heater Current: 25 to 33 Amperes
  • Cathode Heating Time: 15 minutes minimum

Hydrogen Reservoir Function

The hydrogen reservoir controls the internal gas pressure of the thyratron. Adjusting the reservoir voltage controls the temperature of the reservoir capsule:

  • Increased Voltage: Causes the capsule to emit hydrogen, increasing gas pressure.
  • Decreased Voltage: Causes the capsule to absorb hydrogen, decreasing gas pressure.

This adjustment allows the operator to optimize the tube's performance for minimum deionization time, minimum arc-back, and minimum anode heating.

  • Reservoir Voltage: 2.5 to 5.5 Volts. The optimum reservoir voltage for Operation 1 is printed on the base of each individual tube and must be held within ±5%.
  • Reservoir Current: 3 to 6 Amperes at an operating voltage of 4.5 Volts.

Electrical Connections and Lead Designations

The 1754 does not use a standard pin-and-socket base. Instead, electrical connections are made via flexible leads extending from the base. The lead designations are:

  • Cathode & Cathode Heater Center-Tap Lead
  • Heater Leads (2)
  • Grid Lead
  • Reservoir Leads (2)
  • Leads connected in base

The anode connection is made via the top cap.

Absolute Maximum Ratings

The following absolute maximum ratings must not be exceeded under any circumstances. Operating beyond these limits can cause immediate failure or severely degrade tube life.

ParameterAbsolute Maximum Rating
Peak Anode Voltage (epy)25.0 kV
Peak Inverse Anode Voltage (epx)25.0 kV (Must be at least 5% of epy)
Cathode Current Rate of Rise5000 A/µs
Peak Anode Current (Ib)1000 A
Peak Inverse Grid Voltage (egx)450 V
Average Anode Current1.0 A DC
Starting Anode Voltage4 kV DC
Dissipation Factor9.0 x 10^9 (Formula: epy x Ib x prr, up to 1500 pps)
Duty Cycle0.001 (Formula: prr x tp = 0.001)

Grid Drive Requirements

To ensure reliable triggering and prevent jitter or misfiring, the grid drive circuit must deliver a robust pulse. These values are measured at the socket with the grid disconnected:

  • Peak Grid Voltage (egy): 700 Volts Minimum to 1000 Volts Maximum
  • Rate of Rise: 0.35 µs Maximum
  • Grid Pulse Duration: 2.0 µs Minimum
  • Drive Impedance: 50 to 200 Ohms
  • Peak Inverse Grid Voltage (egx): 450 Volts

Operating Conditions and Circuit Constraints

Typical Operation (Operation 1)

Under typical resonant charging conditions, the 1754 operates with the following parameters:

  • Peak Anode Voltage (epy): 25 kV
  • Rate of Rise of Cathode Current: 5000 A/µs
  • Peak Anode Current: 1000 A
  • Anode Pulse Duration: 2.5 µs
  • Pulse Repetition Rate: 360 pps

Circuit-Specific Constraints and Design Considerations

  • Resonant Charging: In typical pulse-forming network (PFN) charging circuits, transient voltage swings the instantaneous plate voltage to approximately double the power supply voltage. This transient swing must be factored into the peak anode voltage rating to ensure the 25.0 kV limit is not exceeded.
  • Instantaneous Starting: Instantaneous starting is not recommended. If it is absolutely necessary, the maximum permissible peak anode voltage (epy) is restricted to 18.0 kV, and this voltage must be attained in no less than 0.04 µs.
  • Post-Pulse Inverse Voltage: The peak inverse voltage must not exceed 5 kV during the first 25 µs immediately following the anode pulse.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
2.53 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Published maximum ratings and characteristics promoted semantically from the approved source.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1950 Sylvania

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Maximum Plate Voltage

    250000 V

  • Maximum Cathode Current

    1000 A

  • Peak Anode Voltage

    250 kV

  • Peak Inverse Anode Voltage

    250 kV

  • Peak Anode Current

    1000 A

  • Cathode Current Rate of Rise

    5000 A/us

  • Average Anode Current

    10 A

  • Duty Cycle

    0.001

Characteristic

  • Starting Anode Voltage

    4 kV

    Maximum

  • Cathode Heating Time

    15 min