Data set 01
1968 General Electric Co
Published operating points and test conditions from this source.
Triode
Other
HeaterOrFilamentVoltageNominal
16 V
HeaterOrFilamentCurrentNominal
315 mA
Voltage Dual Triode Pentode ·Pentode-Triode-Triode
Compactron containing high-mu and medium-mu triodes plus a sharp-cutoff pentode for television video-amplifier and general-purpose signal-processing service.
Compactron containing a high-mu triode, medium-mu triode, and sharp-cutoff pentode for video-amplifier and general-purpose service.
Duodecar 12-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
3 physical sections, each with unique specifications.
Section 1
GE 16BX11 first high-mu or medium-mu distinct triode of Compactron with second triode and sharp-cutoff video pentode. Heater 16 V 315 mA. Maximum plate voltage 330 V and dissipation 2 W. Typical characteristics at plate 150 V: gm 6.2 mA/V, mu 42 and plate resistance ~6800 ohms. GE documents physical separate triode and coupling capacitances. Manufacturer graph/table OCR ambiguity does not affect these explicit ratings.
Section 2
GE 16BX11 second distinct triode, used for general-purpose amplification, sharing 16 V 315 mA heater with first triode and video pentode. Max plate voltage 330 V and dissipation 1.5 W. At published 150 V plate operating point: gm 6.8 mA/V, mu 57, plate resistance ~8400 ohms. Values must remain separate from first triode (mu 42). Manufacturer supplies direct interelectrode capacitances.
Section 3
GE 16BX11 sharp-cutoff frame-grid video-amplifier pentode in 12-pin Compactron with dissimilar dual triodes. Plate dissipation 3 W, screen dissipation 1 W; nominal heater 16 V, 315 mA. Typical pentode at 125 V plate and screen: gm 11.3 mA/V, approximate plate resistance 100 kΩ. Numeric operating maximum plate/screen voltages are left unknown because the scanned source has unresolved OCR ambiguity; do not infer from plate supply or operating values. Capacitance and inter-section coupling figures published.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
HeaterOrFilamentVoltageNominal
16 V
HeaterOrFilamentCurrentNominal
315 mA