Rectifier - Full Wave ·Rectifier-Rectifier
12Y4
12Y4 indirectly heated common-cathode dual-diode full-wave rectifier with British five-pin base, 12.8 V 0.15 A heater and 420 V peak inverse voltage.
- Sections
- 2
- Base
- -
- Socket code
- -
- Base pins
- 5
- Nominal heater
- 12.8 V / 150 mA
General specifications
Tube and section characteristics
Properties common to every published source and operating point.
Heater and base
- Base
- -
- Socket code
- -
- Base pins
- 5
- Nominal heater voltage
- 12.8 V
- Nominal heater current
- 150 mA
- Parallel heater voltage
- -
- Parallel heater current
- -
- Series capable
- No
Terminal pinout
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
Section ratings
2 physical sections, each with unique specifications.
Section 1
Rectifier
- Rectifier peak inverse voltage
- 420 V
- Rectifier nominal output current
- 8 mA
- Rectifier peak forward current
- 50 mA
- Rectifier forward voltage drop
- 8 V
- Rectifier max heater-cathode voltage
- 150 V
RMA 1944 12Y4 plate1 pin4 to common cathode center pin. Per-plate maximum AC supply 150 V RMS, PIV 420 V, peak steady-state current 50 mA, rectified DC output 8 mA. Forward drop 8 V measured at 16 mA DC per plate. Heater-cathode max 150 V DC. Plate1 capacitance to cathode/heater 4.7 pF. Plate-to-plate capacitance 0.7 pF, measured with MS-311 shield connected to cathode.
Section 2
Rectifier
- Rectifier peak inverse voltage
- 420 V
- Rectifier nominal output current
- 8 mA
- Rectifier peak forward current
- 50 mA
- Rectifier forward voltage drop
- 8 V
- Rectifier max heater-cathode voltage
- 150 V
RMA 1944 12Y4 plate2 pin2 to common cathode center pin. Per-plate maximum AC supply 150 V RMS, PIV 420 V, peak steady-state current 50 mA, rectified DC output 8 mA. Forward drop 8 V measured at 16 mA DC per plate. Heater-cathode max 150 V DC. Plate2 capacitance to cathode/heater 5.0 pF. Plate-to-plate capacitance 0.7 pF, measured with MS-311 shield connected to cathode.
Source-dependent data
Operating conditions by source
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.