Data set 01
1970 Sylvania Technical Manual
Published operating points and test conditions from this source.
Beam Power
Other
Plate Voltage
250 V
Average cathode current
175 mA
Maximum average cathode current; Sylvania 1970
Screen Voltage
150 V
Peak positive pulse plate voltage
6500 V
Peak positive plate pulse; Sylvania 1970
Grid Voltage
-22.5 V
Peak negative pulse plate voltage
-1500 V
Peak negative plate pulse; Sylvania 1970
Plate Current
70 mA
Positive DC beam-plate voltage
70 V
DC grid 3 maximum; Sylvania 1970
Screen Current
2.1 mA
Grid #1 voltage
55 V
Maximum negative DC grid 1 voltage (magnitude); Sylvania 1970
Grid To Plate Capacitance
0.26 pF
Peak negative grid #1 voltage
-330 V
Peak negative control-grid pulse; Sylvania 1970
Input Capacitance
15 pF
For grid bias feedback HV regulation
1 MOhm
Maximum grid 1 circuit resistance, grid-resistor-bias operation; Sylvania 1970
Output Capacitance
6.5 pF
Grid #1 voltage
-42 V
Grid 1 voltage at Ib=1 mA; Sylvania 1970
Plate voltage
60 V
Instantaneous knee, screen=150V, grid 1=0V; Sylvania 1970
Plate current
390 mA
Instantaneous plate knee, plate=60V; Sylvania 1970
Grid #2 current
32 mA
Instantaneous screen knee, plate=60V; Sylvania 1970
Bulb Temperature (At hottest point)
240 degC
Maximum bulb temperature; Sylvania 1970
Heater warm-up time
11 s
Average heater warm-up time; Sylvania 1970
Peak Heater-Cathode Voltage
200 V
Heater negative relative to cathode, DC and peak; Sylvania 1970
Peak Heater-Cathode Voltage
100 V
Heater positive relative to cathode, DC; Sylvania 1970
Peak Heater-Cathode Voltage
200 V
Heater positive relative to cathode, DC and peak; Sylvania 1970