Maximum pulse duration
200 microseconds
Published in approved 17DQ6B target datasheet entry; Section1
be reduced to 100 mAwith a maximum pulse duration of
400 microseconds
Published in approved 17DQ6B target datasheet entry; Section1
Heater Voltage (ac/dc) 6.3 12.6
16.8 V
Published in approved 17DQ6B target datasheet entry; Section1
Heater Current 1.2 0.6
450 mA
Published in approved 17DQ6B target datasheet entry; Section1
Heater Warm-up Time (Average) 11
11 seconds
Published in approved 17DQ6B target datasheet entry; Section1
DC Plate Supply Voltage
770 V
Published in approved 17DQ6B target datasheet entry; Section1
Peak Positive-Pulse Plate Voltage*
6500 V
Published in approved 17DQ6B target datasheet entry; Section1
Peak Negative-Pulse Plate Voltage
1500 V
Published in approved 17DQ6B target datasheet entry; Section1
DC Grid-No.2 (Screen-Grid) Voltage
220 V
Published in approved 17DQ6B target datasheet entry; Section1
DC Grid-No.l (Control-Grid) Voltage
55 V
Published in approved 17DQ6B target datasheet entry; Section1
Peak Negative-Pulse Grid-No.l Voltage
330 V
Published in approved 17DQ6B target datasheet entry; Section1
Peak Cathode Current
550 mA
Published in approved 17DQ6B target datasheet entry; Section1
Average Cathode Current
175 mA
Published in approved 17DQ6B target datasheet entry; Section1
Plate Dissipation*
17.5 W
Published in approved 17DQ6B target datasheet entry; Section1
Grid-No.2 Input
3.5 W
Published in approved 17DQ6B target datasheet entry; Section1
Bulb Temperature (At hottest point)
240 °C
Published in approved 17DQ6B target datasheet entry; Section1
Grid-No. 1-Circuit Resistance, for grid-resistor-bias operation
1 MΩ
Published in approved 17DQ6B target datasheet entry; Section1
# Pulse duration must not exceed 15% of a horizontal scanning cycle (
10 microseconds
Published in approved 17DQ6B target datasheet entry; Section1