Exact variations of 12BA6

These designations belong to the same electrical variation group. Their names may differ because of international standards, manufacturing tolerances, or materials, but they are recorded as electrically equivalent—not merely substitutes.

  • HF93

    Voltage Pentode - Remote Cutoff (single)

    Base
    Not recorded
    Socket
    B7G
    Base pins
    7
    Sections
    1
    Heater voltage
    12.6 V
    Heater current
    0.15 A

Replacement tubes for 12BA6

The following tubes are recorded as possible replacements for 12BA6. This direction does not establish that 12BA6 can replace them.

12F31

Voltage Pentode - Sharp Cutoff (single)

Foreign To American

The database records 12F31 as a possible replacement for12BA6.

No special restrictions are recorded for this substitution.

SpecificationOriginal tubeReplacement
Tube typeVoltage Pentode - Remote Cutoff (single)Voltage Pentode - Sharp Cutoff (single)
ConstructionPentodePentode
Base7CCNot recorded
SocketB7GNot recorded
Base pins7Not recorded
Sections11
Heater voltage12.6 V12.6 V
Heater current0.15 A0.15 A
HF93

Voltage Pentode - Remote Cutoff (single)

Foreign To American

The database records HF93 as a possible replacement for12BA6.

No special restrictions are recorded for this substitution.

SpecificationOriginal tubeReplacement
Tube typeVoltage Pentode - Remote Cutoff (single)Voltage Pentode - Remote Cutoff (single)
ConstructionPentodePentode
Base7CCNot recorded
SocketB7GB7G
Base pins77
Sections11
Heater voltage12.6 V12.6 V
Heater current0.15 A0.15 A
HF94

Voltage Pentode

Foreign To American

The database records HF94 as a possible replacement for12BA6.

No special restrictions are recorded for this substitution.

SpecificationOriginal tubeReplacement
Tube typeVoltage Pentode - Remote Cutoff (single)Voltage Pentode
ConstructionPentodePentode
Base7CCNot recorded
SocketB7GB7G
Base pins77
Sections11
Heater voltage12.6 V12.6 V
Heater current0.15 A0.15 A
12AU6

Voltage Pentode - Sharp Cutoff (single)

Receiving Tubes

The database records 12AU6 as a possible replacement for12BA6.

No special restrictions are recorded for this substitution.

SpecificationOriginal tubeReplacement
Tube typeVoltage Pentode - Remote Cutoff (single)Voltage Pentode - Sharp Cutoff (single)
ConstructionPentodePentode
Base7CC7BK
SocketB7GB7G
Base pins77
Sections11
Heater voltage12.6 V12.6 V
Heater current0.15 A0.15 A
12BZ6

Voltage Pentode - Remote Cutoff (single)

Receiving Tubes

The database records 12BZ6 as a possible replacement for12BA6.

  • Not suitable for all circuits
SpecificationOriginal tubeReplacement
Tube typeVoltage Pentode - Remote Cutoff (single)Voltage Pentode - Remote Cutoff (single)
ConstructionPentodePentode
Base7CC7CM
SocketB7GB7G
Base pins77
Sections11
Heater voltage12.6 V12.6 V
Heater current0.15 A0.15 A

Where 12BA6 can be used as the replacement

In these recorded relationships, 12BA6 is the replacement tube. The listed original tubes are not automatically suitable as replacements for 12BA6.

12E13

Power - Beam (NOT sweep)

American To Foreign

The database records 12BA6 as a possible replacement for12E13.

No special restrictions are recorded for this substitution.

Specification12BA6 replacementOriginal tube
Tube typeVoltage Pentode - Remote Cutoff (single)Power - Beam (NOT sweep)
ConstructionPentodeBeamPower
Base7CCNot recorded
SocketB7GIO
Base pins78
Sections11
Heater voltage12.6 V6.3 V
Heater current0.15 A1.6 A
HF93

Voltage Pentode - Remote Cutoff (single)

American To Foreign

The database records 12BA6 as a possible replacement forHF93.

No special restrictions are recorded for this substitution.

Specification12BA6 replacementOriginal tube
Tube typeVoltage Pentode - Remote Cutoff (single)Voltage Pentode - Remote Cutoff (single)
ConstructionPentodePentode
Base7CCNot recorded
SocketB7GB7G
Base pins77
Sections11
Heater voltage12.6 V12.6 V
Heater current0.15 A0.15 A
12AU6

Voltage Pentode - Sharp Cutoff (single)

Receiving Tubes

The database records 12BA6 as a possible replacement for12AU6.

No special restrictions are recorded for this substitution.

Specification12BA6 replacementOriginal tube
Tube typeVoltage Pentode - Remote Cutoff (single)Voltage Pentode - Sharp Cutoff (single)
ConstructionPentodePentode
Base7CC7BK
SocketB7GB7G
Base pins77
Sections11
Heater voltage12.6 V12.6 V
Heater current0.15 A0.15 A
12BD6

Voltage Pentode - Remote Cutoff (single)

Receiving Tubes

The database records 12BA6 as a possible replacement for12BD6.

No special restrictions are recorded for this substitution.

Specification12BA6 replacementOriginal tube
Tube typeVoltage Pentode - Remote Cutoff (single)Voltage Pentode - Remote Cutoff (single)
ConstructionPentodePentode
Base7CCNot recorded
SocketB7GB7G
Base pins77
Sections11
Heater voltage12.6 V12.6 V
Heater current0.15 A0.15 A
12BZ6

Voltage Pentode - Remote Cutoff (single)

Receiving Tubes

The database records 12BA6 as a possible replacement for12BZ6.

  • Not suitable for all circuits
Specification12BA6 replacementOriginal tube
Tube typeVoltage Pentode - Remote Cutoff (single)Voltage Pentode - Remote Cutoff (single)
ConstructionPentodePentode
Base7CC7CM
SocketB7GB7G
Base pins77
Sections11
Heater voltage12.6 V12.6 V
Heater current0.15 A0.15 A

Verify before substituting

Matching a base or heater voltage is not enough to prove that two tubes are interchangeable. Check pin connections, heater current, maximum ratings, bias requirements, warm-up behavior, and the equipment manufacturer’s service documentation before making a substitution.

View the complete 12BA6 specifications →