Skip to main content

Voltage Pentode - Remote Cutoff (single) ·Pentode

12B7ML

Metal remote-cutoff pentode for RF voltage amplification, combining variable-mu gain control with a 12.6 V series heater.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
B8G
Base pins
8
Nominal heater
12.6 V / 150 mA

Description

12B7ML — Remote Cut-Off R.F. Pentode

The 12B7ML (also designated as 12B7(ML)) is a remote cut-off radio-frequency (R.F.) pentode vacuum tube designed for Class A voltage amplifier service. Sponsored by the General Electric Company and registered in July 1939, this metal-envelope tube features an indirectly heated cathode and is constructed with a locking 8-pin base. Its remote cut-off characteristic makes it highly suitable for automatic volume control (AVC) or automatic gain control (AGC) circuits in radio-frequency and intermediate-frequency amplifier stages, where it can handle a wide range of signal amplitudes with minimal distortion.

Physical Construction and Basing

The 12B7ML is constructed with a metal bulb envelope and does not utilize an external top cap, keeping all electrode connections routed through its base. It features a locking 8-pin base with an 8 V basing designation. The physical dimensions of the tube are compact, designed to fit standard equipment layouts:

  • Maximum Diameter: 1 3/16 inches
  • Maximum Overall Length: 2 25/32 inches
  • Maximum Seated Height: 2 1/4 inches

The tube is designed to operate in any mounting position, providing flexibility in physical chassis layout.

The pin connections, viewed from the bottom of the locking 8-pin base, are assigned as follows:

PinConnection
Pin 1Heater
Pin 2Plate
Pin 3Screen Grid (G2G_2)
Pin 4Suppressor Grid (G3G_3)
Pin 5Internal Shield
Pin 6Control Grid (G1G_1)
Pin 7Cathode
Pin 8Heater

The inclusion of an internal shield connected to Pin 5 helps minimize internal coupling and electromagnetic interference, which is critical for stable high-frequency amplification.

Heater and Electrical Ratings

The 12B7ML is equipped with an indirectly heated cathode (heater-type cathode). The heater is designed for operation in 12-volt systems, typically found in automotive or AC/DC receiver designs.

The electrical ratings for the heater and the maximum limits under Class A voltage amplifier service are:

  • Heater Voltage: 12.6 volts
  • Heater Current: 0.15 amperes
  • Maximum Plate Voltage: 250 volts
  • Maximum Screen Voltage (G2G_2): 100 volts

These maximum ratings represent the absolute limits within which the tube must be operated to ensure reliable performance and longevity.

Class A Typical Operation and Characteristics

In Class A voltage amplifier service, the 12B7ML can be operated under different voltage conditions. The typical operating points demonstrate the tube's performance at moderate and maximum rated plate voltages:

ParameterOperating Point IOperating Point II
Plate Voltage100 V250 V
Screen Voltage (G2G_2)100 V100 V
Grid Voltage (G1G_1)-3 V-3 V
Suppressor Voltage (G3G_3)0 V0 V
Plate Resistance0.25 MΩ0.8 MΩ
Transconductance1900 µmhos2000 µmhos
Plate Current8.9 mA9.2 mA
Screen Current2.6 mA2.4 mA

Remote Cut-off Characteristic

As a remote cut-off pentode, the transconductance of the 12B7ML can be varied smoothly over a wide range by adjusting the control grid bias. Under typical operating conditions (with a plate voltage of 250 V and screen voltage of 100 V), applying a grid bias of -35 volts reduces the transconductance to a nominal value of 10 µmhos. This wide bias range allows the tube to handle strong signals without clipping, making it ideal for receiver circuits employing automatic gain control.

Direct Interelectrode Capacitances

To ensure stable operation in high-frequency circuits, the 12B7ML is designed with low direct interelectrode capacitances. The maximum and typical values are:

  • Grid to Plate (G1G_1 to Plate): 0.005 mmf (maximum)
  • Input (G1G_1 to all other electrodes except Plate): 5.5 mmf
  • Output (Plate to all other electrodes except G1G_1): 7.0 mmf

The extremely low grid-to-plate capacitance of 0.005 mmf maximum is achieved through the pentode structure and the internal shield (connected to Pin 5), which minimizes feedback from the plate to the control grid, thereby preventing unwanted oscillations in high-gain R.F. stages.

Technical Summary

The 12B7ML is a metal-envelope, remote cut-off R.F. pentode featuring a locking 8-pin base and an indirectly heated cathode. Operating with a 12.6 V, 0.15 A heater, it is optimized for Class A voltage amplification in radio-frequency and intermediate-frequency stages. With a maximum plate voltage rating of 250 V and screen voltage rating of 100 V, it delivers a transconductance of 1900 to 2000 µmhos under typical operating conditions. Its remote cut-off characteristic is demonstrated by its ability to reduce transconductance to 10 µmhos at a grid bias of -35 V. The combination of low grid-to-plate capacitance (0.005 mmf max), an internal shield, and a robust locking base design makes the 12B7ML a reliable component for stable, high-gain amplification in early electronic receiver designs.

Socket description

Loctal 8-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B8G
Base pins
8
Nominal heater voltage
12.6 V
Nominal heater current
150 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Pentode

X-ray radiationInterelectrode capacitances
Plate resistance
800000 Ω
Transconductance
0.002 S
Max plate voltage
250 V
Max screen voltage
100 V