Skip to main content

Specialized - Thyratron ·Thyratron

1258

Zero-bias miniature hydrogen thyratron for low-power radar pulse-modulator service. Fast gas switching provides rapid, repeatable high-voltage pulses.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
7
Nominal heater
6.3 V / 1.8 A

Description

Zero-bias miniature hydrogen thyratron for low-power radar pulse-modulator service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
7
Nominal heater voltage
6.3 V
Nominal heater current
1.8 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max plate voltage
1000 V
Max cathode current
20 A

Hydrogen thyratron. Specialized pulse/anode/grid ratings are preserved in TUBE_SECTION_PARAMETER because the fixed section schema has no thyratron-specific promoted fields.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1961 Tung Sol

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Peak Anode Voltage Forward

    1000 V

  • Peak Anode Voltage Inverse

    1000 V

  • Peak Cathode Current

    20 A

  • Average Cathode Current

    50 mA

  • RMS Cathode Current

    1 A

  • DC Anode Voltage

    300 V

  • Operating Frequency

    5000 cps

  • Current Rate of Rise

    400 A/us

  • Cathode Heating Time.......... O Ittt Tk

    60 s

  • ... ... .. ... ... Etd

    175 V

  • Avbiaer. .. Ot Ib

    50 mA

  • D.C.Anode Voltage.... ... ... ... ... I Ebb

    300 V

  • Peak Inverse Grid Voltage .................................................. Egx

    150 V

  • Favorable Operating Conditions. With Sufficient Grid Drive And With Anode Vollages Of

    600 V

  • Peak Voltage

    200 V

  • Driver Circuit Impedance

    200 ohm

  • Sess Than

    0.5 us

Characteristic

  • Anode Delay Time

    0.6 us

  • Time Jitter

    0.01 us

  • Anode Voltage Drop

    175 V

Data set 02

1966 Tung Sol Electronic Tubes 3 of 4

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Heater voltage minimum

    5.7 V

  • Heater voltage nominal

    6.3 V

  • Heater voltage maximum

    6.6 V

  • Peak inverse anode voltage

    1000 V

    Pulse

  • Peak forward anode voltage

    1000 V

    Pulse

  • Peak cathode current

    20 A

    Pulse

  • Average cathode current

    50 mA

    Pulse

  • RMS cathode current

    1 A

    SquarePulse

  • DC anode voltage

    500 V

  • Maximum repetition rate life-tested

    5000 Hz

    Pulse

  • Peak grid voltage

    500 V

    Pulse

  • Peak inverse grid voltage

    150 V

    Pulse

  • Current rate of rise

    400 A/us

    Pulse

  • Peak pulse power

    10 kW

    PulseModulator

Characteristic

  • Cathode heating time

    60 s

  • Anode voltage drop maximum

    175 V

  • Anode delay time

    0.6 us

    Pulse

  • Time jitter

    0.01 us

    Pulse