Skip to main content

Rectifier - Half Wave ·Rectifier

1039

Directly heated Philips mercury-vapour or gas-filled industrial rectifier for high-current battery charging. Rated for approximately 185 V peak inverse voltage, 7.5 A average current, and 45 A peak current.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
1.9 V / 20 A

Description

1039 — Double-Anode Rectifying Valve

The 1039 is a mercury vapour and gas-filled, double-anode rectifying valve designed for industrial applications, specifically battery charging. It is capable of delivering up to 15 A per valve and is suitable for charging systems with a maximum of 20 lead-acid (Pb) cells.

Mechanical Design and Physical Dimensions

The 1039 features a robust physical construction designed for vertical, base-down mounting. Its physical dimensions and mechanical characteristics include:

  • Base Type: Goliath base.
  • Compatible Socket/Support: 65909 BG/01.
  • Maximum Overall Height: 264 mm.
  • Maximum Bulb Diameter: 94 mm.
  • Anode Connections: Two M6 screw terminals located at the top of the bulb, spaced 18 mm apart.
  • Weight: Net weight of 340 g, with a shipping weight of approximately 1100 g.

The valve must always be operated in a vertical position with the base down to ensure proper distribution of the mercury fill.

Filament and Heating Requirements

The valve utilizes a directly heated, oxide-coated filament. Due to the mercury-vapour fill, strict heating and timing protocols must be observed to prevent damage to the cathode during start-up:

  • Filament Voltage (VfV_f): 1.9 V (A.C. heating).
  • Filament Current (IfI_f): 20 A.
  • Recommended Preheating Time (TwT_w): 2 minutes. Under urgent conditions, this preheating time may be decreased to a minimum of 1 minute.
  • Special Preheating Conditions: After transport or a long interruption of service, the preheating time (TwT_w) must be extended to 5 minutes.
  • Control Auxiliary: A type 4152 time delay switch can be utilized to ensure the proper delay is maintained before anode voltage is applied.

Electrical and Operating Characteristics

The electrical behavior of the 1039 is characterized by low internal voltage drops typical of gas and mercury-vapour rectifiers. Its primary electrical parameters include:

  • Arc Voltage (VarcV_{\text{arc}}): 9 V
  • Ignition Voltage (VignV_{\text{ign}}): 16 V

Typical Battery Charging Operation

When operated in a typical charging circuit (designated as Circuit a) with an AC transformer voltage (VtrV_{\text{tr}}) of 60 VeffV_{\text{eff}} and a series resistance (RtR_t) of 0.85 Ω\Omega, the operating parameters vary depending on the charge state of the battery bank:

Battery StateBattery Voltage (VbatV_{\text{bat}})Output Current (IoI_o)Peak Anode Current (IapI_{\text{ap}})
Discharged36 V19 A—
Nominal44 V13.5 A37 A
Charged54 V8 A—

Absolute Maximum Ratings

To ensure safe operation and prevent premature failure of the valve, the following absolute limiting values must not be exceeded:

  • Peak Inverse Anode Voltage (VinvpV_{\text{invp}}): Maximum 185 V
  • Average Anode Current (IaI_a): Maximum 7.5 A
  • Peak Anode Current (IapI_{\text{ap}}): Maximum 45 A
  • Series Resistance (RtR_t): Minimum 0.75 Ω\Omega
  • Mercury Temperature (tHgt_{\text{Hg}}): 30°C to 80°C

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
1.9 V
Nominal heater current
20 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
185 V
Rectifier nominal output current
7.5 A
Rectifier peak forward current
45 A
Rectifier forward voltage drop
9 V
Rectifier warm-up time
120 s

Directly heated gas-filled rectifier with mercury-vapour/gas filling for battery charging up to 20 lead-acid cells.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Philips Electron Tubes Handbook V3

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Characteristic

  • Arc voltage drop

    9 V

    GasFilled

Other

  • Maximum peak inverse anode voltage

    185 V

  • Maximum average anode current

    7.5 A

  • Maximum peak anode current

    45 A

  • Application

    battery charging up to 20 lead-acid cells

  • Heater voltage

    1.9 V

    DirectAC

  • Heater current

    20 A

    DirectAC

Data set 02

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • MinimumSeriesResistance

    0.75 ohm

  • NominalBatteryVoltage

    44 V

    BatteryCharger

  • NominalOutputCurrent

    13.5 A

    BatteryCharger

Characteristics

  • TypicalArcVoltage

    9 V

  • IgnitionVoltage

    16 V