Skip to main content

Voltage - Triode (single) ·Triode

102E

Filamentary detector and amplifier triode for low-level signal service, with a 160-volt maximum safe plate voltage.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
UV4
Base pins
4
Nominal heater
2.25 V / 950 mA

Description

102E Vacuum Tube

A triode vacuum tube designed for detector and amplifier service, featuring a high amplification constant and low-voltage filament operation.

Overview

The 102E (also designated as the 102-E) is a vacuum tube designed for use as a detector and an amplifier. It is engineered for compatibility with Western Electric Vacuum Tube Sockets Nos. 100-L or 100-R. The tube features a classic spherical bulb construction with a specialized four-pin bayonet base.

Physical Construction and Basing

The 102E is constructed with a glass envelope having a maximum bulb diameter of 2-3/8 inches and an overall height of 4-1/2 inches. The tube utilizes a cylindrical base equipped with a side-mounted locating pin (bayonet pin) to ensure correct orientation when inserted into its socket.

The base configuration consists of four pins on the bottom, arranged as follows:

  • P: Plate (Anode)
  • F+: Filament positive terminal
  • F-: Filament negative terminal
  • G: Control Grid

The locating pin is positioned on the side of the base adjacent to the filament-negative and grid pins.

Electrical Characteristics and Amplifier Operating Points

When operated as an amplifier, the 102E exhibits specific electrical parameters. The filament is designed for low-voltage, moderate-current operation, and the tube operates with relatively low plate currents and a high amplification factor.

Filament Ratings

  • Normal Filament Voltage: 2 to 2.5 Volts
  • Normal Filament Current: 0.95 Ampere

The filament current is a critical factor in determining the operating life of the tube. To ensure maximum useful life, the filament current should be maintained at the lowest possible level that still secures the desired output. Operating the filament above a current of 1.15 amperes will materially shorten the service life of the tube.

Amplifier Operating Parameters

Under normal operating conditions as an amplifier, the electrical characteristics are defined by the following ranges:

ParameterValue Range
Normal Plate Voltage100 to 150 Volts
Maximum Safe Plate Voltage160 Volts
Normal Grid Voltage0 to -3 Volts
Normal Plate Current0.3 to 1.5 Milliamperes
Plate-to-Filament Impedance40,000 to 100,000 Ohms
Amplification Constant26 to 34

Circuit Applications and Variations

The 102E is versatile, serving as both a detector and an amplifier. While the standard electrical values and operating ranges listed above apply specifically to its use as an amplifier, these parameters are not rigid when the tube is employed in other roles.

When the 102E is configured as a detector or for alternative circuit applications, the applied voltages may be varied to suit the specific requirements of the circuit. Adjusting these applied voltages will result in corresponding variations in the other electrical values, such as plate current and plate-to-filament impedance, allowing the tube to be optimized for different operating conditions.

Technical Summary

The 102E is a detector and amplifier triode characterized by its physical dimensions of 2-3/8 inches in diameter and 4-1/2 inches in height, designed for Western Electric Nos. 100-L or 100-R sockets. It features a four-pin bayonet base with a locating pin. Electrically, it operates with a 2 to 2.5 V filament drawing 0.95 A normally, with a strict maximum limit of 1.15 A to prevent premature filament degradation. In amplifier service, it operates with plate voltages between 100 and 150 V (160 V maximum safe limit), grid bias of 0 to -3 V, and plate currents of 0.3 to 1.5 mA. It provides an amplification constant of 26 to 34 and a plate-to-filament impedance ranging from 40,000 to 100,000 ohms, with adaptable operating parameters when configured for detector applications.

Socket description

WD/UV 4-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
UV4
Base pins
4
Nominal heater voltage
2.25 V
Nominal heater current
950 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
70000 Ω
Amplification factor
30
Max plate voltage
160 V

Early directly heated detector/amplifier triode. Published plate-to-filament impedance 40,000–100,000 ohms and amplification constant 26–34; promoted plate resistance 70,000 ohms and amplification factor 30 are arithmetic midpoints, not separately specified nominal values. Filament voltage 2–2.5 V (stored tube nominal midpoint 2.25 V), current 0.95 A. Exceeding 1.15 A filament current materially shortens life. Datasheet operating values apply to amplifier service.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

2026 Western Electric 100s

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Filament voltage

    2.25 V

  • Filament current

    950 mA

  • Maximum plate voltage

    160 V

  • Filament voltage

    2 to 2.5 V

    Amplifier use

  • Plate current

    0.3 to 1.5 mA

    Amplifier use

  • Plate voltage

    100 to 150 V

    Amplifier use

  • Grid voltage

    0 to 3 V

    Amplifier use

  • Filament current life caution

    1.15 A

    Exceeding this materially shortens life

Characteristic

  • Plate-to-filament impedance

    40000 to 100000 ohm

    Amplifier use

  • Amplification constant

    26 to 34

    Amplifier use