1018 โ Gas-Filled Rectifier Valve
The 1018 is a gas-filled rectifier valve designed specifically for charging purposes. It features a directly heated filament and is rated for low-voltage, moderate-current rectification.
Filament and Heating Specifications
The 1018 utilizes a directly heated cathode configuration. The electrical requirements for the filament are:
- Filament Voltage: 1.8 V
- Filament Current: Approximately 1.8 A
- Calculated Filament Power: 3.24 W
The filament power is calculated directly from the nominal filament voltage of 1.8 V and the approximate filament current of 1.8 A (1.8 V * 1.8 A = 3.24 W).
Anode Ratings and Operating Limits
The anode circuit of the 1018 is rated for low-voltage AC inputs and moderate DC output currents. The maximum operating limits are:
- Maximum AC No-Load Voltage: 16 V R.M.S.
- Maximum DC Current: 200 mA
These ratings define the safe operating envelope of the valve. The maximum AC input voltage must not exceed 16 V R.M.S. under no-load conditions, and the rectified DC current drawn through the anode must not exceed 200 mA.
Construction and Application
The 1018 is classified as a gas-filled valve, distinguishing it from high-vacuum rectifiers. Its primary designated application is as a rectifier for charging purposes.
The physical specifications, including maximum dimensions and base connection references, are not specified in the standard product listings, indicating a specialized design or non-standard physical configuration.
Technical Summary
The 1018 is a directly heated, gas-filled rectifier valve designed for charging applications. It operates with a 1.8 V, 1.8 A filament (3.24 W calculated power) and supports a maximum AC no-load voltage of 16 V R.M.S. with a maximum DC current of 200 mA.