Specialized - Switching Tube ·Thyratron

0A4G

Cold-cathode gas relay tube for heaterless electronic control. Gas ionization provides abrupt conduction for relay, trigger, and switching circuits.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
4V
Socket code
IO
Base pins
4
Nominal heater
0 V / 0 mA

Description

0A4G — Cold-Cathode Gas Triode Relay Tube

Overview

The 0A4G (also written as 0A4-G) is a cold-cathode, gas-filled glow-discharge triode designed primarily for relay service, carrier-current remote control systems, and calculating machines. Because it utilizes a cold cathode, the tube requires no heater or filament power, resulting in zero standby power consumption when the tube is inactive.

The primary operating mechanism of the 0A4G relies on a starter-anode (or starter-electrode) to initiate a glow discharge with a very small amount of electrical energy. Once initiated, this discharge ionizes the internal gas, allowing a much larger current to flow through the main anode-to-cathode circuit. This characteristic makes the 0A4G highly practical for remote control of line-operated electrical devices using radio-frequency (RF) impulses transmitted directly over existing power lines. Additionally, the 0A4G can be configured for use as a voltage regulator or as a relaxation oscillator.

Physical Construction and Basing

The 0A4G is constructed within an ST-12 glass bulb and features a Small Shell Octal 6-Pin base (also designated as the 4V, G-4V, or 8CT basing arrangement). The physical dimensions of the tube are characterized by:

  • Maximum overall length: 4-1/8 inches
  • Maximum diameter: 1-9/16 inches

The tube can be mounted and operated in any position.

The underside view of the octal socket connections reveals the following pin assignments:

  • Pin 1: No Connection (NC)
  • Pin 2: Cathode (K)
  • Pin 3: No Connection (NC)
  • Pin 5: Anode (P2)
  • Pin 7: Starter-Anode (P1)
  • Pin 8: No Connection (NC)

The locating key of the octal base is positioned between Pin 1 and Pin 8.

Electrical Characteristics and Operating Principles

The 0A4G functions by separating the initiation of the gas discharge from the main conduction path. Under normal standby conditions, the voltage applied between the main anode and the cathode is kept below the level required to cause spontaneous breakdown.

Breakdown Voltages and Operating Drops

The electrical behavior of the tube is defined by several critical voltage thresholds and operating drops:

ParameterValue
Peak Anode Breakdown Voltage (Starter-anode tied to cathode)225 V minimum
Peak Positive Starter-Anode Breakdown Voltage70 V minimum / 90 V maximum
Starter-Anode Drop (During conduction)~55 to 60 V
Anode Drop (During main conduction)~70 V
Extinction Voltage< 60 V

Spontaneous breakdown between the main anode and cathode will not occur below 225 V if the starter-anode is tied to the cathode. However, if a positive potential between 70 V and 90 V (typically around 85 V) is applied to the starter-anode relative to the cathode, a localized glow discharge is initiated between these two electrodes.

Transition and Conduction

Once the starter-anode discharge is established, it produces free ions within the gas-filled envelope. If the main anode is at a sufficient positive potential, these ions enable the discharge to transfer to the main anode-to-cathode path. For this transition to occur reliably at an anode potential of 140 peak volts, the starter-anode current must reach a transition threshold:

  • Maximum transition starter-anode current: 100 µA
  • Recommended practical starter-anode current: At least 200 µA

During active conduction, the voltage drop across the starter-anode to cathode is approximately 60 V (with some sources listing a starter-anode drop of 55 V), while the main anode-to-cathode operating drop stabilizes at approximately 70 V.

To extinguish the discharge and return the tube to its non-conducting state, the anode voltage must be reduced below the extinction voltage of 60 V.

Maximum Ratings and Typical Operating Conditions

The 0A4G must be operated within its absolute limits to prevent damage and ensure reliable relay action.

Maximum Ratings (Relay Service)

  • Maximum Peak Cathode Current: 100 mA
  • Maximum D-C (Average) Cathode Current: 25 mA
  • Maximum Peak Inverse Anode Voltage: 225 V

Typical AC Operation

When operated directly from a standard AC power line, the typical operating parameters are:

  • Anode-Supply Voltage (RMS): 105 to 130 V
  • Maximum Peak AC Starter-Anode Voltage: 70 V
  • Minimum Peak RF Starter-Anode Voltage: 55 V
  • Minimum Combined Peak Voltage (AC + RF): 110 V

The combined peak voltage is a calculated sum of the peak AC bias voltage and the peak RF control signal voltage: Sum Voltage = Peak AC Voltage + Peak RF Voltage >= 110 V This ensures that the combined potentials reliably exceed the starter-anode breakdown threshold under low line-voltage conditions.

Circuit Applications and Design Considerations

Carrier-Current Remote Control Relay

The classic application of the 0A4G is a line-operated remote control relay. In this circuit, the full AC line voltage (typically 115 V AC) is applied directly across the main anode and cathode through a relay coil (S).

A resistive voltage divider (bleeder system) consisting of a 15,000 Ω (1/2 watt) resistor (R1R_1) and a 10,000 Ω (1/2 watt) resistor (R2R_2) is connected across the AC line. This divider maintains the starter-anode at an AC bias potential just below the minimum breakdown voltage (70 V peak).

A series-tuned LC circuit, consisting of an inductance (LL) and a capacitor (CC), is connected in series with the line and tuned to the specific frequency of the RF control carrier.

  1. Standby State: In the absence of an RF signal, the starter-anode voltage remains below the breakdown threshold, and no current flows through the tube or the relay.
  2. Triggered State: When an RF carrier of the resonant frequency is impressed on the power line, a resonant voltage appears across LL and CC. The voltage across capacitor CC increases the negative potential peaks on the cathode, which effectively increases the potential difference between the cathode and the starter-anode.
  3. Breakdown and Transfer: This increased potential initiates a discharge between the cathode and the starter-anode. The resulting ionization allows the discharge to transfer to the main anode.
  4. Relay Activation: Current flows through the main anode circuit, energizing the relay coil (SS) to close a local circuit. An optional capacitor (such as a 25 µF capacitor) may be placed across the relay coil to smooth the half-wave rectified current.
  5. Automatic Reset: Because the anode is supplied with AC, the anode voltage drops below the extinction threshold (and reverses polarity) during the negative half of each AC cycle. Consequently, the 0A4G automatically ceases to conduct and resets as soon as the RF carrier signal is removed.

DC Operation

The 0A4G can also be operated from a DC power source. However, because DC voltage does not pass through zero, the tube will not automatically extinguish once triggered. The main anode current will continue to flow indefinitely even after the starter-anode signal is removed. To reset the circuit, an external mechanism (such as a normally closed switch or relay contact) must be provided to open the anode circuit or reduce the anode potential below 60 V.

Design Precautions

When designing circuits around the 0A4G, two opposing conditions must be carefully balanced:

  • High Line-Voltage Safety: At the highest expected line voltage, the AC bias voltage delivered to the starter-anode by the bleeder circuit must not be high enough to cause spontaneous breakdown in the absence of a signal.
  • Low Line-Voltage Reliability: At the lowest expected line voltage, the RF carrier signal must provide a high enough peak voltage (minimum 55 V peak) to ensure that the sum of the AC bias and RF voltages reliably triggers the starter-anode.

Breakdown Characteristics and Quadrants

The breakdown behavior of the 0A4G is highly dependent on the polarities of the starter-anode and the main anode relative to the cathode. These relationships are mapped across four quadrants:

  • First Quadrant (Starter-Anode Positive, Anode Positive): This is the intended operating region. The tube exhibits stable, predictable breakdown characteristics. Breakdown between the cathode and starter-anode occurs at approximately 85 V, which successfully initiates the main anode discharge if the anode potential is adequate.
  • Other Quadrants (Negative Polarities): Operating the tube in quadrants where the starter-anode or the main anode is negative relative to the cathode results in highly unstable and unpredictable breakdown behavior. Circuit designs should avoid these regions.

Related Designations

  • 1C21: The 1C21 is a cold-cathode glow-discharge tube that is physically and electrically similar to the 0A4G, but it is specifically designed and rated for DC operation only.
  • 5823: The 5823 is a miniature 7-pin cold-cathode relay tube. While it performs a similar 'on-off' control function for low-current circuits, it utilizes a different physical structure and a miniature 7-pin base rather than the octal configuration of the 0A4G.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
4V
Socket code
IO
Base pins
4
Nominal heater voltage
0 V
Nominal heater current
0 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

4V - Terminal pinout

Electrical assignments shared by every tube using this base designation.

TerminalSectionConnectionEvidence
PIN2KAK — CathodeUnverified

EIA Base Connections, printed page 127, 4V

PIN5PAP — Plate (Anode)Unverified

EIA Base Connections, printed page 127, 4V

PIN7G1AG1 — Control GridUnverified

EIA Base Connections, printed page 127, 4V

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max plate voltage
225 V
Max cathode current
25 mA

Published handbook ratings and operating characteristics reviewed.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1940 RCA

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • StarterAnodeRFVoltageMinimum

    55 V peak

  • AnodeVoltageMinimum

    110 V peak

Data set 02

195X General Electric Essential Characteristics

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Peak cathode current

    100 mA

    GasTriodeService

  • DC cathode current

    25 mA

    GasTriodeService

Characteristic

  • Starter anode drop

    55 V

    GasTriodeService

  • Anode drop

    70 V

    GasTriodeService

Data set 03

195X Raytheon Special Purpose Tubes

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Maximum peak inverse anode voltage

    225 V

  • Maximum peak cathode current

    100 mA

  • Maximum average cathode current

    25 mA

Characteristic

  • Peak starter-anode breakdown voltage

    75 to 90 V

Data set 04

1960 RCA Industrial and Communications Types

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Peak Inverse Anode Voltage

    225 V

  • PeakCathodeCurrentMaximum

    100 mA

Characteristic

  • StarterElectrodeBreakdownVoltageMinimum

    75 V

  • StarterElectrodeBreakdownVoltageMaximum

    90 V