Data set 01
1940 RCA
Published operating points and test conditions from this source.
Thyratron
Characteristic
StarterAnodeRFVoltageMinimum
55 V peak
AnodeVoltageMinimum
110 V peak
Specialized - Switching Tube ·Thyratron
Cold-cathode gas relay tube for heaterless electronic control. Gas ionization provides abrupt conduction for relay, trigger, and switching circuits.
The 0A4G (also written as 0A4-G) is a cold-cathode, gas-filled glow-discharge triode designed primarily for relay service, carrier-current remote control systems, and calculating machines. Because it utilizes a cold cathode, the tube requires no heater or filament power, resulting in zero standby power consumption when the tube is inactive.
The primary operating mechanism of the 0A4G relies on a starter-anode (or starter-electrode) to initiate a glow discharge with a very small amount of electrical energy. Once initiated, this discharge ionizes the internal gas, allowing a much larger current to flow through the main anode-to-cathode circuit. This characteristic makes the 0A4G highly practical for remote control of line-operated electrical devices using radio-frequency (RF) impulses transmitted directly over existing power lines. Additionally, the 0A4G can be configured for use as a voltage regulator or as a relaxation oscillator.
The 0A4G is constructed within an ST-12 glass bulb and features a Small Shell Octal 6-Pin base (also designated as the 4V, G-4V, or 8CT basing arrangement). The physical dimensions of the tube are characterized by:
The tube can be mounted and operated in any position.
The underside view of the octal socket connections reveals the following pin assignments:
The locating key of the octal base is positioned between Pin 1 and Pin 8.
The 0A4G functions by separating the initiation of the gas discharge from the main conduction path. Under normal standby conditions, the voltage applied between the main anode and the cathode is kept below the level required to cause spontaneous breakdown.
The electrical behavior of the tube is defined by several critical voltage thresholds and operating drops:
| Parameter | Value |
|---|---|
| Peak Anode Breakdown Voltage (Starter-anode tied to cathode) | 225 V minimum |
| Peak Positive Starter-Anode Breakdown Voltage | 70 V minimum / 90 V maximum |
| Starter-Anode Drop (During conduction) | ~55 to 60 V |
| Anode Drop (During main conduction) | ~70 V |
| Extinction Voltage | < 60 V |
Spontaneous breakdown between the main anode and cathode will not occur below 225 V if the starter-anode is tied to the cathode. However, if a positive potential between 70 V and 90 V (typically around 85 V) is applied to the starter-anode relative to the cathode, a localized glow discharge is initiated between these two electrodes.
Once the starter-anode discharge is established, it produces free ions within the gas-filled envelope. If the main anode is at a sufficient positive potential, these ions enable the discharge to transfer to the main anode-to-cathode path. For this transition to occur reliably at an anode potential of 140 peak volts, the starter-anode current must reach a transition threshold:
During active conduction, the voltage drop across the starter-anode to cathode is approximately 60 V (with some sources listing a starter-anode drop of 55 V), while the main anode-to-cathode operating drop stabilizes at approximately 70 V.
To extinguish the discharge and return the tube to its non-conducting state, the anode voltage must be reduced below the extinction voltage of 60 V.
The 0A4G must be operated within its absolute limits to prevent damage and ensure reliable relay action.
When operated directly from a standard AC power line, the typical operating parameters are:
The combined peak voltage is a calculated sum of the peak AC bias voltage and the peak RF control signal voltage: Sum Voltage = Peak AC Voltage + Peak RF Voltage >= 110 V This ensures that the combined potentials reliably exceed the starter-anode breakdown threshold under low line-voltage conditions.
The classic application of the 0A4G is a line-operated remote control relay. In this circuit, the full AC line voltage (typically 115 V AC) is applied directly across the main anode and cathode through a relay coil (S).
A resistive voltage divider (bleeder system) consisting of a 15,000 Ω (1/2 watt) resistor () and a 10,000 Ω (1/2 watt) resistor () is connected across the AC line. This divider maintains the starter-anode at an AC bias potential just below the minimum breakdown voltage (70 V peak).
A series-tuned LC circuit, consisting of an inductance () and a capacitor (), is connected in series with the line and tuned to the specific frequency of the RF control carrier.
The 0A4G can also be operated from a DC power source. However, because DC voltage does not pass through zero, the tube will not automatically extinguish once triggered. The main anode current will continue to flow indefinitely even after the starter-anode signal is removed. To reset the circuit, an external mechanism (such as a normally closed switch or relay contact) must be provided to open the anode circuit or reduce the anode potential below 60 V.
When designing circuits around the 0A4G, two opposing conditions must be carefully balanced:
The breakdown behavior of the 0A4G is highly dependent on the polarities of the starter-anode and the main anode relative to the cathode. These relationships are mapped across four quadrants:
International Octal
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN2K | A | K — Cathode | Unverified EIA Base Connections, printed page 127, 4V |
| PIN5P | A | P — Plate (Anode) | Unverified EIA Base Connections, printed page 127, 4V |
| PIN7G1 | A | G1 — Control Grid | Unverified EIA Base Connections, printed page 127, 4V |
1 physical section, each with unique specifications.
Section 1
Published handbook ratings and operating characteristics reviewed.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
StarterAnodeRFVoltageMinimum
55 V peak
AnodeVoltageMinimum
110 V peak
Data set 02
Published operating points and test conditions from this source.
Peak cathode current
100 mA
GasTriodeService
DC cathode current
25 mA
GasTriodeService
Starter anode drop
55 V
GasTriodeService
Anode drop
70 V
GasTriodeService
Data set 03
Published operating points and test conditions from this source.
Maximum peak inverse anode voltage
225 V
Maximum peak cathode current
100 mA
Maximum average cathode current
25 mA
Peak starter-anode breakdown voltage
75 to 90 V
Data set 04
Published operating points and test conditions from this source.
Peak Inverse Anode Voltage
225 V
PeakCathodeCurrentMaximum
100 mA
StarterElectrodeBreakdownVoltageMinimum
75 V
StarterElectrodeBreakdownVoltageMaximum
90 V