Data set 01
1953 Amperex
Published operating points and test conditions from this source.
Voltage Regulator
Characteristics
Operating voltage nominal
150 V
Other
Minimum anode supply voltage
185 V
Voltage Regulator ·VoltageRegulator
Cold-cathode gas voltage regulator providing a nominal 150 V stabilized reference over roughly 5–30 mA without heater power.
A cold-cathode, glow-discharge, gas-filled miniature diode designed to provide a stable 150-volt DC output across a variable load or from a fluctuating supply voltage.
The 0A2 is a cold-cathode, gas-filled voltage regulator (also referred to as a voltage stabilizer) housed in a miniature glass envelope. It is designed to maintain a sensibly constant DC operating voltage of approximately 150 V across a load, accommodating moderate variations in both the load current and the unregulated supply voltage.
The tube operates on the principle of a glow discharge within an inert gas atmosphere. Unlike vacuum tubes with heated filaments, the 0A2 does not contain a heater, making it a cold-cathode device. It is widely utilized in power supply regulation, voltage reference circuits, and industrial applications. The device is also designated under service types such as CV1832 and CV8161.
The 0A2 is constructed using a miniature glass bulb (T-5 1/2 outline) with a miniature button 7-pin base. The physical dimensions of the tube are highly standardized:
| Dimension | Maximum Value (Inches) | Maximum Value (Metric) |
|---|---|---|
| Overall Length | 2.618 in (or 2 5/8 in) | 66.5 mm |
| Seated Height | 2.366 in | 60.1 mm |
| Bulb Diameter | 0.748 in (or 3/4 in) | 19.0 mm |
The tube uses the B7G (or B.S.448-B7G, JETEC 5BO) base configuration. The pin connections, viewed from the bottom of the base, are assigned as follows:
The duplicate anode (Pins 1 and 5) and cathode (Pins 2, 4, and 7) connections are not merely redundant; they are designed to be wired as an integrated safety disconnect. By routing the unregulated input voltage through Pin 5 and taking the regulated output from Pin 1, removing the 0A2 from its socket physically breaks the connection to the load. This prevents high, unregulated voltage from reaching and potentially damaging downstream components.
The 0A2 can be mounted and operated in any position.
The electrical behavior of the 0A2 is defined by its ionization (striking) voltage, its nominal operating voltage, and its current-handling limits.
Before the tube can conduct and regulate, the voltage across its electrodes must reach the striking (or ionization) voltage to initiate the gas discharge. This striking voltage is sensitive to ambient light levels:
To guarantee reliable starting throughout the operating life of the tube, a minimum DC anode supply voltage of 185 V must be provided under normal lighting conditions.
Once ionization occurs, the voltage across the tube drops to its nominal operating voltage of 150 V. At a typical operating current of 17.5 mA, the regulated voltage is guaranteed to fall within the range of 144 V to 164 V (with some specifications defining a wider range of 140 V to 168 V).
The 0A2 is rated for a continuous DC operating current range of 5 mA to 30 mA. Within this range, the tube exhibits excellent voltage regulation:
The tube also exhibits low electrical noise, with a maximum root-mean-square (r.m.s.) noise voltage of 5.0 mV over a frequency range of 50 to 5000 Hz when operating within its rated current limits.
To prevent damage and ensure stable operation, the 0A2 must be operated within its absolute maximum limits:
| Parameter | Absolute Limit |
|---|---|
| Maximum Continuous DC Cathode Current | 30 mA |
| Minimum Continuous DC Cathode Current | 5 mA |
| Maximum Average Starting Current | 75 mA |
| Maximum Averaging Time (for starting current) | 10 seconds |
| Maximum Parallel (Shunt) Capacitance | 0.1 µF |
| Ambient Temperature Range | -55 °C to +90 °C |
| Maximum Operating Frequency | 0 cycles/sec (DC only) |
| Maximum Unpressurized Altitude | 3000 meters |
The tube must always be operated with the correct polarity: the anode must be positive with respect to the cathode. Reverse polarity will degrade the tube and prevent proper regulation.
The 0A2 cannot be connected directly across a voltage source. A series resistor must always be placed between the unregulated supply voltage and the tube's anode. This resistor serves two critical functions:
The value of the series resistor is calculated based on the maximum unregulated supply voltage, the minimum load current, and the nominal 150 V operating drop of the tube.
To prevent parasitic relaxation oscillations, any capacitor connected in parallel with the 0A2 must be strictly limited to a maximum value of 0.1 µF. If a larger capacitance is placed directly across the tube, the combination of the tube's negative resistance characteristic and the capacitor will form an oscillator, causing severe voltage instability and potential damage to the tube.
As a gas-filled device, the 0A2 exhibits specific behaviors related to its operational history and temperature:
For applications requiring higher regulated voltages, multiple 0A2 tubes can be connected in series. For example, two 0A2 tubes connected in series can provide a stabilized output of approximately 300 V, with an intermediate regulated tap of 150 V available at the junction between the two tubes. In such configurations, the safety disconnect wiring should be maintained across all tubes in the string so that removing any single tube safely de-energizes the entire load circuit.
Several ruggedized and military-grade versions of the 0A2 exist to meet specialized requirements:
The 0A2 is a miniature, cold-cathode, gas-filled voltage regulator designed to provide a stable 150 V DC output. Operating over a current range of 5 mA to 30 mA, it maintains voltage stability within a maximum of 6 V (typically 2 V). It features a 7-pin miniature base (B7G) with duplicate anode and cathode pins that can be wired as a safety disconnect. To ensure reliable starting, a minimum supply voltage of 185 V is required under normal lighting, which must be increased to 225 V if the device is operated in complete darkness. Ruggedized equivalents include the 6073 for high shock and vibration environments, and the military-grade 6626/0A2-WA.
Miniature 7-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published handbook ratings and operating characteristics reviewed.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Operating voltage nominal
150 V
Minimum anode supply voltage
185 V
Data set 02
Published operating points and test conditions from this source.
Minimum anode supply voltage
185 V
VoltageRegulatorService
Maximum operating current
30 mA
VoltageRegulatorService
Minimum operating current
5 mA
VoltageRegulatorService
Operating voltage
150 V
VoltageRegulatorService
Ionization voltage
155 V
VoltageRegulatorService
Regulation
2 V
5 to 30 mA
Data set 03
Published operating points and test conditions from this source.
Operating voltage
150 V
Maximum regulation
6 V
5to30mA
Minimum operating current
5 mA
Maximum operating current
30 mA
Minimum starting-voltage supply
185 V
Data set 04
Published operating points and test conditions from this source.
Minimum DC Anode Supply Voltage
185 V
Regulation
2 V
5 to 30 mA
Data set 05
Published operating points and test conditions from this source.
DC operating voltage
150 V
DC operating current minimum
5 to - mA
DC operating current maximum
- to 30 mA
DC starting voltage
155 V
Approximate
Voltage regulation
- to 2 V
Ia=5-30mA
Data set 06
Published operating points and test conditions from this source.
StrikingVoltage
185 V
MaintainingCurrentMinimum
5 mA
MaintainingCurrentMaximum
30 mA
Data set 07
Published operating points and test conditions from this source.
Operating voltage
150 V
Approximate
Cathode current range
5 mA to 30 mA
Striking voltage in normal lighting
185 V
Striking voltage in total darkness
225 V
Data set 08
Published operating points and test conditions from this source.
StartingCurrent
75 mA
Regulation
6 V
Ia=5-30 mA