Skip to main content

Specialized tube type

Specialized - X-Ray Tube vacuum tubes

Specialized - X-Ray Tube records in Tube Tinker cover 36 tube designations, including 71 preserved original datasheets. Compare bases, sockets, heater requirements, construction, exact variations, and directional replacement options.

Search this type in the catalog →
Tube records
36
Original datasheets
71
Variation families
0
Tubes with alternatives
0

About Specialized - X-Ray Tube tubes

If the tube is described as an x-ray tube then apply this type.

Electrical range

Nominal heater voltage
2.7 V
Nominal heater current
1.95 A

Common specialized - x-ray tube characteristics

These are the most frequently recorded attributes among tubes in this category.

Bases

  • InternationalOctal2

Sockets

  • IO1

Constructions

  • XRay36

Specialized - X-Ray Tube tube list

Page 1 of 1

Open advanced catalog filters →
  • 4072A

    XRay

    Self-rectifying X-ray tube for direct transformer operation at 63 kV peak and 10 mA mean current, with a 1.5 mm square focal spot.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    2.7 V
    Sections
    1
  • 5519

    XRay

    Oil-cooled Westinghouse diagnostic X-ray tube with dual 2.1 and 4.2 mm focal spots for high-voltage fluoroscopic and radiographic service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5520

    XRay

    Westinghouse diagnostic X-ray tube with a 1.5 mm focal spot, air/oil cooling, and peak plate-voltage ratings to approximately 110 kV.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5521

    XRay

    Westinghouse diagnostic X-ray tube with a 2.1 mm focal spot, air/oil cooling, and peak plate-voltage ratings to approximately 110 kV.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5522

    XRay

    Westinghouse diagnostic X-ray tube with a 3.0 × 2.0 mm focal spot, air/oil cooling, and high-capacity 110 kV service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5523

    XRay

    Westinghouse diagnostic X-ray tube with a 4.2 mm focal spot, air/oil cooling, and peak plate-voltage ratings to approximately 100 kV.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5532

    XRay

    Air-cooled Westinghouse diagnostic X-ray tube with a 2.1 mm focal spot and approximately 100 kV peak plate-voltage capability.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5533

    XRay

    Air-cooled Westinghouse diagnostic X-ray tube with a 3.0 mm focal spot and approximately 100 kV peak plate-voltage capability.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5534

    XRay

    Air-cooled Westinghouse diagnostic X-ray tube with a 4.2 mm focal spot and approximately 100 kV peak plate-voltage capability.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5535

    XRay

    Air-cooled Westinghouse diagnostic X-ray tube with dual 2.1 and 4.2 mm focal spots and approximately 100 kV high-voltage capability.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5536

    XRay

    Air-cooled Westinghouse diagnostic X-ray tube with a 2.1 mm focal spot, increased heat capacity, and approximately 100 kV operation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5537

    XRay

    Air-cooled diagnostic X-ray tube designed for approximately 100 kV radiographic and fluoroscopic service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5538

    XRay

    Air-cooled diagnostic X-ray tube intended for approximately 100 kV radiographic and fluoroscopic applications.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5539

    XRay

    Air-cooled diagnostic X-ray tube for approximately 100 kV radiographic and fluoroscopic high-voltage service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5540

    XRay

    Air-cooled diagnostic X-ray tube designed for radiographic and fluoroscopic operation at peak plate voltages to approximately 100 kV.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5599

    XRay

    Oil-cooled diagnostic X-ray tube designed for high-voltage radiographic service with approximately 125 kV peak plate-voltage capability.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5600

    XRay

    Oil-cooled diagnostic X-ray tube intended for high-voltage radiographic service with approximately 125 kV peak plate-voltage capability.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5601

    XRay

    Oil-cooled diagnostic X-ray tube for high-voltage medical radiography, rated for approximately 125 kV peak plate voltage.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5602

    XRay

    Oil-cooled diagnostic X-ray tube designed for high-voltage radiographic operation with approximately 125 kV peak plate-voltage capability.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5711

    XRay

    Oil-cooled X-ray insert tube designed for superficial-therapy service with peak plate-voltage capability around 120 kV.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5712

    XRay

    Forced-oil-cooled superficial-therapy X-ray tubehead incorporating a 5711 insert for therapeutic operation to approximately 120 kV.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5745

    XRay

    Oil-cooled diagnostic X-ray tube designed for approximately 75 kV peak plate-voltage radiographic service.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5746

    XRay

    Oil-cooled diagnostic X-ray tube intended for radiographic service at peak plate voltages around 75 kV.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5747

    XRay

    Oil-cooled diagnostic X-ray tube for approximately 75 kV peak high-voltage radiographic operation.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5748

    XRay

    Oil-cooled diagnostic X-ray tube designed for radiographic service with approximately 75 kV peak plate-voltage capability.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5781

    XRay

    Removable-insert air-cooled X-ray tube for regular-duty diagnostic service with approximately 100 kV peak plate-voltage capability.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • 5782

    XRay

    Removable-insert air-cooled X-ray tube for heavy-duty diagnostic service with approximately 100 kV peak plate-voltage capability.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • B110

    XRay

    B110 specialized - x-ray tube electronic tube specifications and datasheets.

    Base
    InternationalOctal
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • B120

    XRay

    Low-power copper-target X-ray tube for radiography of plastics and thin metals, with grid-controlled focus and operation to approximately 25 kV.

    Base
    InternationalOctal
    Socket
    IO
    Heater
    Not recorded
    Sections
    1
  • B210D

    XRay

    Demountable water-cooled copper-target X-ray tube with replaceable filament and window, rated to 40 kV and 400 W for low-voltage radiography.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH9412B

    XRay

    High-resolution 16 cm X-ray image intensifier converting fluoroscopic X-ray patterns into bright visible images with approximately 10,000-fold luminance gain.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH9415

    XRay

    Compact electronic-zoom X-ray image-intensifier tube for medical radiology, providing selectable 16 and 10 cm input fields with high brightness gain.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH9417

    XRay

    Electronic-zoom X-ray image-intensifier tube with dual input fields, high resolution, high contrast, and high luminance gain for radiological imaging.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH9421S

    XRay

    Large-field X-ray image-intensifier tube designed for radiological imaging, combining high contrast with high luminance gain.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • TH9426

    XRay

    Compact electronic-zoom X-ray image-intensifier tube for medical radiology, providing selectable 22, 16, and 11.5 cm input fields with high brightness gain.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    Not recorded
    Sections
    1
  • X63C1

    XRay

    Self-rectifying X-ray generating tube for direct high-tension transformer operation at approximately 63 kV peak and 10 mA mean current, with a 1.5 mm square focal spot.

    Base
    Not recorded
    Socket
    Not recorded
    Heater
    2.7 V
    Sections
    1